MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circulationaha.113.002744

Медицинская библиотека · Circulation · 2013

Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging.

Doukky Rami, Hayes Kathleen, Frogge Nathan, Balakrishnan Gautam, Dontaraju Venkata Satish, Rangel Maria O, Golzar Yasmeen, Garcia-Sayan Enrique, Hendel Robert C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Appropriate use criteria (AUC) have been developed to aid in the optimal use of single-photon emission computed tomography (SPECT)-myocardial perfusion imaging (MPI), a technique that is a mainstay of risk assessment for ischemic heart disease. The impact of appropriate use on the prognostic value of SPECT-MPI is unknown.

METHODS AND

RESULTS

A prospective cohort study of 1511 consecutive patients undergoing outpatient, community-based SPECT-MPI was conducted. Subjects were stratified on the basis of the 2009 AUC for SPECT-MPI into an appropriate or uncertain appropriateness group and an inappropriate group. Patients were prospectively followed up for 27±10 months for major adverse cardiac events of death, death or myocardial infarction, and cardiac death or myocardial infarction. In the entire cohort, the 167 subjects (11%) with an abnormal scan experienced significantly higher rates of major adverse cardiac events and coronary revascularization than those with normal MPI. Among the 823 subjects (54.5%) whose MPIs were classified as appropriate (779, 51.6%) or uncertain (44, 2.9%), an abnormal scan predicted a multifold increase in the rates of death (9.2% versus 2.6%; hazard ratio, 3.1; P=0.004), death or myocardial infarction (11.8% versus 3.3%; hazard ratio, 3.3; P=0.001), cardiac death or myocardial infarction (6.7% versus 1.7%; hazard ratio, 3.7; P=0.006), and revascularization (24.7% versus 2.7%; hazard ratio, 11.4; P<0.001). Among the 688 subjects (45.5%) with MPI classified as inappropriate, an abnormal MPI failed to predict major adverse cardiac events, although it was associated with a high revascularization rate. Furthermore, appropriate MPI use provided incremental prognostic value beyond myocardial perfusion and ejection fraction data.

CONCLUSIONS

When performed for appropriate indications, SPECT-MPI continues to demonstrate high prognostic value. However, inappropriate use lacks effectiveness for risk stratification, further emphasizing the need for optimal patient selection for cardiac testing.

Для цитирования: Doukky Rami, Hayes Kathleen, Frogge Nathan, Balakrishnan Gautam, Dontaraju Venkata Satish, Rangel Maria O, Golzar Yasmeen, Garcia-Sayan Enrique, Hendel Robert C. Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging.. Circulation. 2013. DOI: 10.1161/circulationaha.113.002744.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.