MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-025-07607-6

Медицинская библиотека · BMC oral health · 2026

Three-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns.

Awad Sarah Zaman Sahib, Mourad Khloud Ezzat, Sameh Ahmed, Albaqawi Ahmed Heji, Mostafa Aisha Zakaria Hashem

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to evaluate the biomechanical behavior and stress distribution of tooth–implant-supported telescopic prostheses using different combinations of zirconia, polyetherketoneketone (PEKK), and cobalt–chromium (Co-Cr) materials for primary and secondary crowns by means of three-dimensional finite element analysis (3D FEA). MATERIALS AND

METHODS

A three-dimensional finite element model representing a mandibular arch restored with a telescopic overdenture supported by two canines and two implants in the molar region was constructed. Nine prosthetic configurations were analyzed based on different primary and secondary crown material combinations (zirconia, PEKK, and Co-Cr). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Static axial occlusal loads simulating centric occlusion were applied. Von Mises stress distribution was evaluated in prosthetic components, implants, natural teeth, and surrounding bone.

RESULTS

Material selection significantly influenced stress distribution within the telescopic system and supporting structures. PEKK used as a secondary crown reduced stress concentrations within the prosthetic crowns but resulted in increased stress transfer to the supporting bone, teeth, and implants compared with zirconia and Co-Cr. When PEKK was used as a primary crown, stress levels within prosthetic components were reduced, while stress transmission to supporting structures was not substantially altered. Zirconia and Co-Cr demonstrated comparable biomechanical behavior across all configurations. In all models, secondary crowns exhibited higher stress values than primary crowns, and implants were subjected to greater loads than natural teeth.

CONCLUSIONS

Within the limitations of this 3D finite element study, material combinations in tooth–implant-supported telescopic prostheses significantly affect biomechanical stress distribution. PEKK exhibits a material-dependent stress-modulating behavior that should be carefully considered during prosthetic design to balance prosthetic protection and load transfer to supporting structures.

Для цитирования: Awad Sarah Zaman Sahib, Mourad Khloud Ezzat, Sameh Ahmed, Albaqawi Ahmed Heji, Mostafa Aisha Zakaria Hashem. Three-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns.. BMC oral health. 2026. DOI: 10.1186/s12903-025-07607-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.