Critchfield A S, Paulus J K, Farez R, Urato A C
Аннотация
OBJECTIVE: To determine if serum screen analytes identify preeclamptic patients at risk for small-for-gestational age newborns, maternal laboratory abnormalities and preterm delivery (<37 weeks gestation).
STUDY DESIGN: Using a retrospective cohort of 102 preeclamptic patients, associations between serum screen analytes and newborn birth-weight percentile, gestational age (GA) at delivery and maternal pre-delivery laboratory abnormalities were evaluated using correlation coefficients and local polynomial regression.
RESULT: Inhibin-A and maternal serum alpha fetoprotein were inversely correlated with newborn birth-weight percentile (-0.27, P=0.006; -0.35, P=0.00004) and delivery GA (r=-0.42, P<0.0001; r=-0.26, P=0.008) and positively correlated with pre-delivery aspartate aminotransferase (r=0.22, P=0.03; r=0.21, P=0.04) and lactate dehydrogenase (r=0.33, P=0.0007; r=0.29, P=0.004). A positive correlation was noted between both second-trimester beta human chorionic gonadotropin and estriol and maternal pre-delivery creatinine (0.28, P=0.004; 0.4, P<0.0001, respectively). Hundred percent of patients with ≥ 2 abnormal analytes delivered before 37 weeks gestation.
CONCLUSION: Preeclamptic patients with abnormal serum screen analytes are more likely to have small-for-gestational age newborns, deliver preterm and have pre-delivery laboratory abnormalities.
STUDY DESIGN: Using a retrospective cohort of 102 preeclamptic patients, associations between serum screen analytes and newborn birth-weight percentile, gestational age (GA) at delivery and maternal pre-delivery laboratory abnormalities were evaluated using correlation coefficients and local polynomial regression.
RESULT: Inhibin-A and maternal serum alpha fetoprotein were inversely correlated with newborn birth-weight percentile (-0.27, P=0.006; -0.35, P=0.00004) and delivery GA (r=-0.42, P<0.0001; r=-0.26, P=0.008) and positively correlated with pre-delivery aspartate aminotransferase (r=0.22, P=0.03; r=0.21, P=0.04) and lactate dehydrogenase (r=0.33, P=0.0007; r=0.29, P=0.004). A positive correlation was noted between both second-trimester beta human chorionic gonadotropin and estriol and maternal pre-delivery creatinine (0.28, P=0.004; 0.4, P<0.0001, respectively). Hundred percent of patients with ≥ 2 abnormal analytes delivered before 37 weeks gestation.
CONCLUSION: Preeclamptic patients with abnormal serum screen analytes are more likely to have small-for-gestational age newborns, deliver preterm and have pre-delivery laboratory abnormalities.
Предметные рубрики MeSH
AdultBirth WeightChorionic Gonadotropin, beta Subunit, HumanEstriolFemaleGestational AgeHELLP SyndromeHumansInfant, NewbornInfant, Small for Gestational AgeInhibinsMaternal Serum Screening TestsPre-EclampsiaPregnancyPregnancy ProteinsPregnancy Trimester, SecondPregnancy-Associated Plasma Protein-APremature BirthRetrospective Studiesalpha-Fetoproteins