MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/molecules26226797

Медицинская библиотека · Molecules (Basel, Switzerland) · 2021

HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women.

Mikulska Aniceta A, Filipowicz Dorota, Główka Franciszek K, Szczepanek-Parulska Ewelina, Ruchała Marek, Bartecki Michał, Karaźniewicz-Łada Marta

СтатьяПеревод в очереди

Аннотация

Iodine is an essential component for fetal neurodevelopment and maternal thyroid function. Urine iodine is the most widely used indicator of iodine status. In this study, a novel validated ion-pair HPLC-UV method was developed to measure iodine concentration in clinical samples. A sodium thiosulfate solution was added to the urine sample to convert the total free iodine to iodide. Chromatographic separation was achieved in a Pursuit XRs C8 column. The mobile phase consisted of acetonitrile and a water phase containing 18-crown-6-ether, octylamine and sodium dihydrogen phosphate. Validation parameters, such as accuracy, precision, limits of detection and quantification, linearity and stability, were determined. Urinary samples from pregnant women were used to complete the validation and confirm the method's applicability. In the studied population of 93 pregnant women, the median UIC was lower in the group without iodine supplementation (117 µg/L, confidence interval (%CI): 95; 138) than in the supplement group (133 µg/L, %CI: 109; 157). In conclusion, the newly established ion-pair HPLC-UV method was adequately precise, accurate and fulfilled validation the criteria for analyzing compounds in biological fluids. The method is less complicated and expensive than other frequently used assays and permits the identification of the iodine-deficient subjects.

Для цитирования: Mikulska Aniceta A, Filipowicz Dorota, Główka Franciszek K, Szczepanek-Parulska Ewelina, Ruchała Marek, Bartecki Michał, Karaźniewicz-Łada Marta. HPLC Analysis of the Urinary Iodine Concentration in Pregnant Women.. Molecules (Basel, Switzerland). 2021. DOI: 10.3390/molecules26226797.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.