MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aas.14401

Медицинская библиотека · Acta anaesthesiologica Scandinavica · 2024

Effect of decreasing PEEP on hyperinflation and collapse in COVID-19: A computed tomography study.

Santini Alessandro, Protti Alessandro, Pennati Francesca, Dalla Corte Francesca, Martinetti Nicolò, Pugliese Luca, Picardo Giorgio, Chiurazzi Chiara, Ferrari Michele, Costantini Elena, Aliverti Andrea, Cecconi Maurizio

СтатьяПеревод в очереди

Аннотация

BACKGROUND

High positive end-expiratory pressure (PEEP>10 cmH2O) is commonly used in mechanically ventilated hypoxemic patients with COVID-19. However, some epidemiological and physiological studies indirectly suggest that using a lower PEEP may primarily and beneficially decrease lung hyperinflation in this population. Herein we directly quantified the effect of decreasing PEEP from 15 to 10 cmH2O on lung hyperinflation and collapse in mechanically ventilated patients with COVID-19.

METHODS

Twenty mechanically ventilated patients with COVID-19 underwent a lung computed tomography (CT) at PEEP of 15 and 10 cmH2O. The effect of decreasing PEEP on lung hyperinflation and collapse was directly quantified as the change in the over-aerated (density below -900 HU) and non-aerated (density above -100 HU) lung volumes. The net response to decreasing PEEP was computed as the sum of the change in those two compartments and expressed as the change in the "pathologic" lung volume. If the pathologic lung volume decreased (i.e., hyperinflation decreased more than collapse increased) when PEEP was decreased, the net response was considered positive; otherwise, it was considered negative.

RESULTS

On average, the ratio of arterial tension to inspiratory fraction of oxygen (PaO2:FiO2) in the overall study population was 137 (119-162) mmHg. In 11 (55%) patients, the net response to decreasing PEEP was positive. Their over-aerated lung volume decreased by 159 (98-186) mL, while the non-aerated lung volume increased by only 58 (31-91) mL. In nine (45%) patients, the net response was negative. Their over-aerated lung volume decreased by 46 (18-72) mL, but their non-aerated lung volume increased by 107 (44-121) mL.

CONCLUSION

In 20 patients with COVID-19 the net response to decreasing PEEP, as assessed with lung CT, was variable. In approximately half of them it was positive (and possibly beneficial), with a decrease in hyperinflation larger than the increase in collapse.

Для цитирования: Santini Alessandro, Protti Alessandro, Pennati Francesca, Dalla Corte Francesca, Martinetti Nicolò, Pugliese Luca, Picardo Giorgio, Chiurazzi Chiara, Ferrari Michele, Costantini Elena, Aliverti Andrea, Cecconi Maurizio. Effect of decreasing PEEP on hyperinflation and collapse in COVID-19: A computed tomography study.. Acta anaesthesiologica Scandinavica. 2024. DOI: 10.1111/aas.14401.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.