MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajog.2008.04.049

Медицинская библиотека · American journal of obstetrics and gynecology · 2008

Visually estimated and calculated blood loss in vaginal and cesarean delivery.

Stafford Irene, Dildy Gary A, Clark Steven L, Belfort Michael A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective of the study was to compare visually estimated blood loss (vEBL) with calculated estimated blood loss (cEBL) according to mode of delivery and degree of perineal laceration.

STUDY

DESIGN

Pre- and postdelivery hematocrit (HCT) and other variables including vEBL were prospectively recorded into an obstetrical database between January and September 2005. The cEBL was derived by multiplying the calculated pregnancy blood volume (0.75 x {[maternal height (inches) x 50] + [maternal weight in pounds x 25]}) by percent of blood volume lost ({predelivery HCT - postdelivery HCT}/predelivery HCT). cEBL and vEBL were compared according to mode of delivery and degree of perineal laceration.

RESULTS

There were 677 subjects with complete data. vEBL was statistically different from cEBL between each degree of laceration and between all modes of delivery, demonstrating an underestimation of vEBL with increasing cEBL.

CONCLUSION

Improved methods for calculating blood loss include the use of a modified version of the formula used for pregnancy blood volume calculation.

Для цитирования: Stafford Irene, Dildy Gary A, Clark Steven L, Belfort Michael A. Visually estimated and calculated blood loss in vaginal and cesarean delivery.. American journal of obstetrics and gynecology. 2008. DOI: 10.1016/j.ajog.2008.04.049.