DOI 10.1016/j.preghy.2022.07.004
Evaluation of a protein-to-creatinine dipstick diagnostic test for proteinuria screening in selected antenatal care clinics in three Districts in the Bono-East Region of Ghana.
Аннотация
BACKGROUND
Preeclampsia and eclampsia contribute significantly to maternal and newborn deaths worldwide. Early and accurate identification of pregnant women at risk can avert these deaths, but the necessary diagnostics are not widely available. A protein and creatinine ratio, rather than a measurement of protein alone, may provide better identification of proteinuria. The objective of this study was to assess the operational and performance characteristics of the LifeAssay Diagnostics (LAD) Test-it™ protein-to-creatinine ratio (PrCr) urinalysis dipstick test in a representative antenatal care setting (ANC).
METHODS
Mixed methods were used to assess the operational and performance characteristics of the PrCr test, including a usability study with 25 participants, a prospective cross-sectional diagnostic accuracy study (N = 1483), and a targeted reassessment of discordant frozen samples (N = 200). Several other commonly used proteinuria tests were included for comparison.
RESULTS
The test demonstrated improved clinical performance for detection of proteinuria over the current standard-of-care tests widely used in Ghana. The LAD PrCr test showed a sensitivity of 50.7% and specificity of 69.2% when run at the point of care. In contrast, the standard-of-care Accu-Tell® protein dipstick test was found to have a sensitivity of 32.4% and a specificity of 82.2%. The LAD test shows minor improvement over the tests currently used in Ghana to detect proteinuria.
CONCLUSIONS
The PrCr test offers the potential for improved detection of proteinuria over the standard-of-care tests used in ANC. However, this test and the others evaluated for this study demonstrate limited performance, particularly among samples with a low level of proteinuria. Additional exploration in other clinical use cases, such as triage among high-risk populations, is warranted. The LAD test can also be considered a transition product, as health systems consider adopting next-generation biomarker tests when more readily available.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.