Journal of pharmaceutical and biomedical analysis · 2016

Stereoselective determination of citalopram and desmethylcitalopram in human plasma and breast milk by liquid chromatography tandem mass spectrometry.

СтатьяВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Weisskopf Etienne, Panchaud Alice, Nguyen Kim An, Grosjean Delphine, Hascoët Jean-Michel, Csajka Chantal, Eap Chin B, Ansermot Nicolas, collaborators of the SSRI-Breast Milk study

Аннотация

A high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS) method was developed for the simultaneous, stereoselective quantification of the antidepressant citalopram and its active metabolite desmethylcitalopram in human plasma and breast milk. Sample preparation was performed by a two-step approach, including generic protein precipitation with acetonitrile followed by solid phase extraction. Enantiospecific separation of analytes was achieved on a Phenomenex® Lux Cellulose-2 column (4.6mm×150mm; 5μm), using reversed phase chromatography conditions characterized by a gradient elution of ammonium acetate buffer (pH 9.0; 20mM) and acetonitrile at a flow rate of 0.6ml/min. The compounds were detected by a tandem quadrupole mass spectrometer equipped with an electrospray ionization source and operating in multiple reaction monitoring mode. The method was fully validated in both biological fluids over a large concentration range of 0.1-100ng/ml for S-(+)- and R-(-)-citalopram, and 0.3-100ng/ml for S-(+)- and R-(-)-desmethylcitalopram. Trueness (90.0-113.3% and 97.1-103.6%), repeatability (0.9-15.9% and 0.9-8.4%) and intermediate precision (1.3-17.8% and 0.9-9.6%) in plasma and breast milk, respectively, meet international guidelines for method validation. Internal standard-normalized matrix effects ranged between 99 and 101% and 98-105%, respectively. The accuracy profiles (total error of trueness and precision) were mostly within the acceptance limits for biological samples defined as ±30%. The method was successfully applied to patient samples in a clinical trial setting.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты