DOI 10.1016/j.xphs.2025.103978

Медицинская библиотека · Journal of pharmaceutical sciences · 2025

The capillary-tube-evaporative-concentration (CTEC) method: A new protein-sparing approach to directly determine protein apparent solubility values for antibody developability assessments.

Luan Xi, Camarda Kyle, Lou Hao, Lovell Scott, B Volkin David, Hageman Michael

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Solubility behavior is an important attribute to rank-order monoclonal and bispecific antibody (mAb, biAb) candidates during developability assessments. Current approaches to directly measure antibody solubility without adding precipitating additives (e.g., centrifugal ultrafiltration, protein powder rehydration) have limitations including high protein consumption (∼tens of mgs) and protein instability (e.g., aggregation or gel formation). In this work, we describe the Capillary-Tube-Evaporative-Concentrating (CTEC) method, a new approach to directly measure apparent solubility values from solid-liquid phase separation with only ∼one mg of protein. Proof-of-concept was first established with l-Tryptophan by comparing CTEC measured apparent solubility values with literature reports and theoretical calculations. Second, using the model protein lysozyme at three different pHs, CTEC determined apparent solubility values agreed well with orthogonal solubility measurements and literature reports. Third, we obtained apparent solubility values by CTEC for an IgG1 mAb at different pHs. We then rank-ordered the solubility behavior of three mAbs and one biAb at three different pHs using the CTEC assay and the commonly-used polyethylene glycol precipitation assay. Overall, rank-ordering results correlated well, but in some cases, complemented each other. The potential use of the CTEC solubility assay to directly screen antibody candidates with improved solubility behavior during developability assessments is discussed.

Для цитирования: Luan Xi, Camarda Kyle, Lou Hao, Lovell Scott, B Volkin David, Hageman Michael. The capillary-tube-evaporative-concentration (CTEC) method: A new protein-sparing approach to directly determine protein apparent solubility values for antibody developability assessments.. Journal of pharmaceutical sciences. 2025. DOI: 10.1016/j.xphs.2025.103978.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.