MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41393-020-0423-9

Медицинская библиотека · Spinal cord · 2020

The safety and feasibility of a new rehabilitation robotic exoskeleton for assisting individuals with lower extremity motor complete lesions following spinal cord injury (SCI): an observational study.

Xiang Xiao-Na, Ding Ming-Fu, Zong Hui-Yan, Liu Yan, Cheng Hong, He Cheng-Qi, He Hong-Chen

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

STUDY

DESIGN

A pre-post observational study.

OBJECTIVES

To evaluate the safety and feasibility of a new rehabilitation robotic device for assisting individuals with lower extremity motor complete lesions following spinal cord injury (SCI).

SETTING

Three hospitals in Sichuan Province, China.

METHODS

Individuals aged 15-75 years with an SCI between vertebrae six (T6) and lumbar 1 (L1) and complete motor paralysis participated in an exoskeletal-assisted walking (EAW) programme (2 weeks, 5 days/week, 30 min/day). Data were collected pre-, mid- (week 1) and post-intervention (week 2).

RESULTS

Twenty-eight individuals (mean age = 41.3, 71% males) participated in the EAW programme. The distance walked during the 6-min walking test (6MWT) increased relative to that at baseline, during week 1 (13.0 ± 5.3 m) and week 2 (16.2 ± 5.3 m) when wearing the exoskeleton. The walking speed during the 10-m walking test (10MWT) increased from 0.039 ± 0.016 to 0.045 ± 0.016 m/s. The Hoffer walking ability grade, the Spinal Cord Independence Measure (SCIM), and the Walking Index for SCI II (WISCI II) changed after 2 weeks of EAW. No improvement in lower extremity motor score (LEMS) was observed. The rates of adverse events and serious adverse events were 21% and 4%, respectively.

CONCLUSIONS

The EAW programme with the new robotic exoskeleton provided potential meaningful improvements in mobility for individuals with SCI and had few adverse events.

Для цитирования: Xiang Xiao-Na, Ding Ming-Fu, Zong Hui-Yan, Liu Yan, Cheng Hong, He Cheng-Qi, He Hong-Chen. The safety and feasibility of a new rehabilitation robotic exoskeleton for assisting individuals with lower extremity motor complete lesions following spinal cord injury (SCI): an observational study.. Spinal cord. 2020. DOI: 10.1038/s41393-020-0423-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.