m+Medelevator.RU
← Поиск публикаций
Environmental science & technology · 2005

Pilot-scale demonstration of surfactant-enhanced PCE solubilization at the Bachman Road site. 2. System operation and evaluation.

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ramsburg C Andrew, Pennell Kurt D, Abriola Linda M, Daniels Gary, Drummond Chad D, Gamache Matt, Hsu Hsin-Lan, Petrovskis Erik A, Rathfelder Klaus M, Ryder Jodi L, Yavaraski Thomas P

Аннотация

A pilot-scale demonstration of surfactant-enhanced aquifer remediation (SEAR) was conducted during the summer of 2000 at the Bachman Road site in Oscoda, MI. Part two of this two-part paper describes results from partitioning and nonpartitioning tracer tests, SEAR operations, and post-treatment monitoring. For this field test, 68 400 L of an aqueous solution of 6% (wt) Tween 80 were injected to recover tetrachloroethene-nonaqueous phase liquid (PCE-DNAPL) from a shallow, unconfined aquifer. Results of a nonreactive tracer test, conducted prior to introducing the surfactant solution, demonstrate target zone sweep and hydraulic control, confirming design-phase model predictions. Partitioning tracer test results suggest PCE-DNAPL saturations of up to 0.74% within the pilot-scale treatment zone, consistent with soil core data collected during site characterization. Analyses of effluent samples taken from the extraction well during SEAR operations indicate that a total of 19 L of PCE and 95% of the injected surfactant were recovered. Post-treatment monitoring indicated that PCE concentrations at many locations within the treated zone were reduced by as much as 2 orders of magnitude from pre-SEAR levels and had not rebounded 450 days after SEAR operations ceased. Pilot-scale costs ($365 900) compare favorably with design-phase cost estimates, with approximately 10% of total costs attributable to the intense sampling density and frequency. Results of this pilot-scale test indicate that careful design and implementation of SEAR can result in effective DNAPL mass removal and a substantial reduction in aqueous concentrations within the treated source zone under favorable geologic conditions

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты