Analytica chimica acta · 2023
Hybrid chain reaction and selective recognition-based homogeneous dual-fluorescence analysis of circulating tumor cells in clinical ovarian cancer samples.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hu Qian, Tang Dan, Li Mei, Liang Xiaodu, Zhou Juan, Meng Yanming, Wei Yinhao, Yan Shixin, Lin Ruoyu, Niu Xiaoyu, Zhang Lin
Аннотация
BACKGROUND: Oncological analysis is important in tumor diagnosis. We constructed a dual-fluorescence and binary visual analysis system for circulating tumor cells (CTCs) using the folate receptor as a biomarker, combined with hybridization chain reaction and nanomaterial amplification. This strategy integrates terminal protection, selective recognition properties of N-methyl mesoporphyrin IX and CdTe quantum dots for Cu2+ and double-stranded templated copper nanoparticles, and inkjet printing technology.
RESULTS: In fluorescence mode, folate receptor and A2780 ovarian cancer cells were specifically detected with a limit of detection of 0.1 fg mL-1, and 10 cells mL-1 were observed. The detection limits of both the color and distance reading modes were comparable to those obtained in fluorescence mode. The applicability of the method for quantifying CTCs was validated using 27 (6 negative and 21 positive) clinical ovarian cancer samples; the results agreed with those of both the clinical folate receptor-polymerase chain reaction kit and radiological and pathological results.
SIGNIFICANCE: This dual-fluorescence and binary visual CTCs detection method provides multiple options for clinical tumor liquid biopsy.
RESULTS: In fluorescence mode, folate receptor and A2780 ovarian cancer cells were specifically detected with a limit of detection of 0.1 fg mL-1, and 10 cells mL-1 were observed. The detection limits of both the color and distance reading modes were comparable to those obtained in fluorescence mode. The applicability of the method for quantifying CTCs was validated using 27 (6 negative and 21 positive) clinical ovarian cancer samples; the results agreed with those of both the clinical folate receptor-polymerase chain reaction kit and radiological and pathological results.
SIGNIFICANCE: This dual-fluorescence and binary visual CTCs detection method provides multiple options for clinical tumor liquid biopsy.