Vascular and endovascular surgery · 2017
Concomitant Staple Aneurysmorrhaphy and Flow-Calibrated Arteriovenous Fistula Banding Over a Coronary Dilator to Treat Hand Steal Syndrome.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Baker Jennifer, Malgor Rafael D
Аннотация
BACKGROUND: True venous aneurysm formation can occur in patients with arteriovenous fistulas (AVFs) for hemodialysis but association with steal syndrome is uncommon.
METHODS: To describe a case of a patient on chronic hemodialysis through a right brachiocephalic fistula, who presents with associated steal syndrome and true arteriovenous access aneurysm.
RESULTS: A 34-year-old female with true AVF aneurysm presented with hand steal syndrome confirmed by noninvasive studies. The patient underwent a successful vein aneurysmorrhaphy with a commercially available stapler device and duplex ultrasound flow-calibrated banding. At 1-year follow-up, she remains pain free and the fistula remains functional with no recurrence of venous aneurysmal degeneration.
CONCLUSION: The use of a commercially available surgical stapler devices along with flow-calibrated banding guided by duplex ultrasound over a coronary dilator during the same operation is an elegant, efficacious, and a durable alternative for patients with hand steal syndrome and concomitant AVF aneurysms.
METHODS: To describe a case of a patient on chronic hemodialysis through a right brachiocephalic fistula, who presents with associated steal syndrome and true arteriovenous access aneurysm.
RESULTS: A 34-year-old female with true AVF aneurysm presented with hand steal syndrome confirmed by noninvasive studies. The patient underwent a successful vein aneurysmorrhaphy with a commercially available stapler device and duplex ultrasound flow-calibrated banding. At 1-year follow-up, she remains pain free and the fistula remains functional with no recurrence of venous aneurysmal degeneration.
CONCLUSION: The use of a commercially available surgical stapler devices along with flow-calibrated banding guided by duplex ultrasound over a coronary dilator during the same operation is an elegant, efficacious, and a durable alternative for patients with hand steal syndrome and concomitant AVF aneurysms.