MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2016.03.036

Медицинская библиотека · Journal of chromatography. A · 2016

In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples.

Clavijo Sabrina, Avivar Jessica, Suárez Ruth, Cerdà Víctor

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A novel online approach involving in-syringe magnetic stirring assisted dispersive liquid-liquid microextraction and derivatization coupled to gas chromatography-mass spectrometry has been developed for the determination of seven UV filters extensively used in cosmetic products in environmental water samples. The effect of parameters such as the type and volume of extraction solvent, dispersive solvent and derivatization agent, pH, ionic strength and stirring time, was studied using multivariate experimental design. Extraction, derivatization and preconcentration were simultaneously performed using acetone as dispersive solvent, N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) as derivatization agent and trichloroethylene as extraction solvent. After stirring during 160s, the sedimented phase was transferred to a rotary micro-volume injection valve (3 μL) and introduced by an air stream into the injector of the GC through a stainless-steel tube used as interface. The detection limits were in the range of 0.023-0.16 μg L(-1) and good linearity was observed up to 500 μg L(-1) of the studied UV filters, with R(2) ranging between 0.9829 and 0.9963. The inter-day precision expressed as relative standard deviation (n=5) varied between 5.5 and 16.8%. Finally, the developed method was satisfactorily applied to assess the occurrence of the studied UV filters in seawater and pool water samples. Some of the studied UV filters were found in these samples and an add-recovery test was also successfully performed with recoveries between 82 and 111%.

Для цитирования: Clavijo Sabrina, Avivar Jessica, Suárez Ruth, Cerdà Víctor. In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction and silylation prior gas chromatography-mass spectrometry for ultraviolet filters determination in environmental water samples.. Journal of chromatography. A. 2016. DOI: 10.1016/j.chroma.2016.03.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.