MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5414/cp202128

Медицинская библиотека · International journal of clinical pharmacology and therapeutics · 2014

Pharmacokinetic and bioequivalence assessment of two formulations of tianeptine sodium in healthy male volunteers.

Lei Dongzhu, Li Shaoyuan, Banerjee Santasree, Zhang Haoqing, Li Caiyun, Hou Shuai, Chen Danjing, Yan Haiying, Li Hanmei, Peng Huan Huan, Liu Saijun, Zhang Xinxin, Peng Zhiyu, Wang Jian, Yang Huanming, Huang Hui, Wu Jing

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Tianeptine is widely used for controlling depressive symptoms.

OBJECTIVE

The aim of this study was to evaluate the bioequivalence between the generic (test) formulation containing tianeptine sodium 12.5 mg and the branded (reference) formulation Stablon® with regard to their pharmacokinetic profiles.

METHODS

A randomized, two-sequence, two-treatment crossover study was conducted in healthy male Korean volunteers. All of the enrolled subjects were allocated to one of two sequence groups. They were administered a tablet of the test or reference formulation and then administered the alternative formulation after a 7-day washout period. The blood samples were taken before dosing and at 0.33, 0.67, 1, 1.5, 2, 2.5, 3, 3.5, 4, 6, 8, and 10 hours after dosing. The plasma concentrations of tianeptine were analyzed using high-performance liquid chromatography with tandem mass spectrometer. Tolerability was assessed throughout the study.

RESULTS

The pharmacokinetic parameters were assessed in the 40 subjects who completed the study. The tianeptine C(max) for the test formulation was 283.13 ± 57.58 ng/mL (mean ± SD) and that for the reference formulation was 272.50 ± 59.00 ng/mL. The AUC(last) of tianeptine was 803.24 ± 180.94 ng×h/mL for the test formulation and 792.27 ± 180.93 ng×h/mL for the reference formulation. The geometric mean ratio (%) of the test to reference formulation was 104.04 (90% CI, 99.66 - 108.61) for C(max) and 101.30 (98.01 - 104.71) for AUC(last). Clinically significant adverse events were not reported during the study.

CONCLUSION

The test and reference formulations of tianeptine were bioequivalent with regard to the pharmacokinetic parameters of Cmax and AUC(last). Both formulations were tolerated by all of the participants.

Для цитирования: Lei Dongzhu, Li Shaoyuan, Banerjee Santasree, Zhang Haoqing, Li Caiyun, Hou Shuai, Chen Danjing, Yan Haiying, Li Hanmei, Peng Huan Huan, Liu Saijun, Zhang Xinxin, Peng Zhiyu, Wang Jian, Yang Huanming, Huang Hui, Wu Jing. Pharmacokinetic and bioequivalence assessment of two formulations of tianeptine sodium in healthy male volunteers.. International journal of clinical pharmacology and therapeutics. 2014. DOI: 10.5414/cp202128.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.