Threshold-based artefact correction methods influence heart rate variability measurements in individuals with type 2 diabetes mellitus.

Bassi-Dibai Daniela, Santos-de-Araújo Aldair Darlan, Rocha Daniel Santos, de Almeida Lucivalda Viegas, Figueiredo José Kléber, Gondim Louise Aline Romão, de Farias Diniz Marinete Rodrigues, Frutuoso Victória Pereira, Maia Mariana Campos, Santos Patrícia Martins, Borghi-Silva Audrey

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

Heart rate variability (HRV) is a clinical marker used to assess autonomic function, and the application of filtering algorithms may significantly influence data quantification and interpretation. Although HRV has been extensively studied in individuals with type 2 diabetes mellitus (T2DM), the impact of artefact correction methods remains underexplored. To evaluate the effects of different artefact correction filters in Kubios software on short-term HRV parameters in individuals with T2DM. This cross-sectional, descriptive, and observational study included adults (≥ 18 years) diagnosed with T2DM. Anthropometric and metabolic data were collected, including fasting blood samples for glucose, insulin, and lipid profiles. HRV indices were analyzed across time-domain, frequency-domain, nonlinear, and global metrics. Statistical analysis was performed using ANOVA or Friedman tests according to data distribution, with significance set at p < 0.05. The sample consisted of 52 individuals (67% male, mean age 52 ± 8 years, mean BMI 29.65 ± 5.50 kg/m²). The median duration of T2DM was 3 years (IQR 1.5–10). Median metabolic parameters were insulin 12.50 µU/mL, triglycerides 141.50 mg/dL, fasting glucose 149.50 mg/dL, and HbA1c 8.65% (IQR 7.20–10.00). Application of the most restrictive artefact correction setting (“very strong”) in Kubios significantly modified overall HRV as well as time-domain, frequency-domain, and nonlinear parameters (p < 0.05), highlighting its influence on HRV quantification. This study demonstrates that artefact correction filters, particularly the “very strong” setting, substantially affect HRV analysis in individuals with T2DM. Excessively restrictive filtering may distort autonomic metrics and potentially bias interpretation. Standardization of artefact correction methods is essential to ensure accurate and reproducible HRV assessment in clinical and research settings.

Для цитирования: Bassi-Dibai Daniela, Santos-de-Araújo Aldair Darlan, Rocha Daniel Santos, de Almeida Lucivalda Viegas, Figueiredo José Kléber, Gondim Louise Aline Romão, de Farias Diniz Marinete Rodrigues, Frutuoso Victória Pereira, Maia Mariana Campos, Santos Patrícia Martins, Borghi-Silva Audrey. Threshold-based artefact correction methods influence heart rate variability measurements in individuals with type 2 diabetes mellitus.. Scientific reports. 2026. DOI: 10.1038/s41598-026-42255-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.