MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-021-02618-9

Медицинская библиотека · Journal of orthopaedic surgery and research · 2021

Modified pedicle screw-rod versus anterior subcutaneous internal pelvic fixation for unstable anterior pelvic ring fracture: a retrospective study and finite element analysis.

Pan Zhi-Hong, Chen Fan-Cheng, Huang Jun-Ming, Sun Cheng-Yi, Ding Sheng-Long

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study compared the stability and clinical outcomes of modified pedicle screw-rod fixation (MPSRF) and anterior subcutaneous internal pelvic fixation (INFIX) for the treatment of anterior pelvic ring fractures using the Tornetta and Matta grading system and finite element analyses (FEA).

METHODS

In a retrospective review of a consecutive patient series, 63 patients with Orthopaedic Trauma Association (OTA)/Arbeitsgemeinschaft für Osteosynthesefragen (AO) type B or C pelvic ring fractures were treated by MPRSF (n = 30) or INFIX (n = 33). The main outcome measures were the Majeed score, incidence of complications, and adverse outcomes, and fixation stability as evaluated by finite element analysis.

RESULTS

Sixty-three patients were included in the study, with an average age of 34.4 and 36.2 in modified group and conventional group, respectively. Two groups did not differ in terms of the injury severity score, OTA classification, cause of injury, and time to pelvic surgery. However, the MPSRF group had a rate of higher satisfactory results according to the Tornetta and Matta grading system than the conventional group (73.33% vs 63.63%) as well as a higher Majeed score (81.5 ± 10.4 vs 76.3 ± 11.2), and these differences were statistically significant at 6 months post-surgery. FEA showed that MPSRF was stiffer and more stable than INFIX and had a lower risk of implant failure.

CONCLUSIONS

Both MPSRF and INFIX provide acceptable biomechanical stability for the treatment of unstable anterior pelvic ring fractures. However, MPSRF provides better fixation stability and a lower risk of implant failure, and can thus lead to better clinical outcomes. Therefore, MPSRF should be more widely applied to anterior pelvic ring fractures.

Для цитирования: Pan Zhi-Hong, Chen Fan-Cheng, Huang Jun-Ming, Sun Cheng-Yi, Ding Sheng-Long. Modified pedicle screw-rod versus anterior subcutaneous internal pelvic fixation for unstable anterior pelvic ring fracture: a retrospective study and finite element analysis.. Journal of orthopaedic surgery and research. 2021. DOI: 10.1186/s13018-021-02618-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.