m+Medelevator.RU
← Поиск публикаций
EJNMMI radiopharmacy and chemistry · 2026

Fully GMP-complient radiosynthesis of [161Tb]Tb-PSMA-1 using the miniAiO synthesizer for clinical translation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kryza David, Le Fur Pierre, Badel Jean Noël, Morgat Clément, Khayi Fouzi, Giraudet Anne-Laure

Аннотация

BACKGROUND: Terbium‑161 (161Tb) is an emerging radionuclide for targeted radionuclide therapy that combines β⁻ emissions with short‑range conversion and Auger electrons, increasing its efficacy against micrometastatic and low‑volume prostate cancer. This study aimed to develop, optimize, and validate a fully automated good manufacturing practice (GMP)-compliant radiosynthesis of [161Tb]Tb-PSMA‑1 for clinical application. Radiolabeling parameters were systematically investigated via different buffer systems (acetate, ammonium acetate, and ascorbate), labeling temperatures (24-95 °C), and ethanol supplementation. Process validation was performed on three independent batches produced under routine conditions (7.4-11.5 GBq) via a Trasis MiniAiO synthesizer. Comprehensive quality control included radionuclidic identification, radiochemical purity (RCP), pH, sterility, endotoxin testing, and container-content interaction assessment.

RESULTS: Efficient radiolabeling was achieved under all the tested conditions, with RCPs consistently exceeding 97%. Optimal performance was observed when ascorbate buffer was used at 95 °C, yielding approximately 99% RCP at the end of synthesis. The addition of 40% (V/V) ethanol improved both the labeling efficiency and radiochemical stability, enabling high RCP even at lower temperatures. The final formulation demonstrated excellent stability, maintaining RCP ≥ 97.5% up to 48 h post-synthesis. All validation batches met predefined release criteria in accordance with Ph. Eur. Monograph radiopharmaceutical preparations. The total synthesis time was less than 30 min.

CONCLUSION: A robust, rapid, and fully automated GMP-compliant method for [161Tb]Tb-PSMA‑1 production was successfully established. The high radiochemical purity, stability, and reproducibility support its suitability for routine clinical use and decentralized distribution. This work represents a key step toward the clinical translation of [161Tb]Tb-labeled PSMA radioligands for improved management of advanced prostate cancer.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты