MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3400/avd.oa.22-00089

Медицинская библиотека · Annals of vascular diseases · 2022

Procedure and Aortic Remodeling Effects of Entry Closure with Stentgraft for Type B Aortic Dissection: Comparison between the Patients with Narrow True Lumen and Those with Aneurysmal Dilated False Lumen.

Aoki Atsushi, Maruta Kazuto, Masuda Tomoaki, Omoto Tadashi

СтатьяПеревод в очереди

Аннотация

Objectives

Appropriateness of device selection, procedure protocol and aortic remodeling effects of entry closure (TEVAR) with stent-graft (SG) for patent false lumen type B aortic dissection (TBAD) were compared between the patients with narrow true lumen (narrow group) and those with aneurysmal dilated false lumen (aneurysmal group).

Methods

Twenty-six patients with narrow true lumen (narrow group) and 20 patients with aneurysmal false lumen (aneurysmal group) were included in this study. In narrow group, straight SG was implanted from Zone 3 regardless the distance between the left subclavian artery and entry. In aneurysmal group, straight or taped SG was implanted with proximal landing zone length 20 mm or more. Thoracic aortic anatomy was evaluated by CT and aortic remodeling was defined as true lumen diameter ≥50% of the aortic diameter and occlusion of false lumen. Aorta related death, retrograde type A aortic dissection (RTAD), stentgraft induced new entry (SINE) and aortic maximum diameter enlargement 5 mm or more (aortic expansion) were included in the aortic event.

Results

There was no procedure related complication in narrow group and 1 patient died due to aortic rupture in aneurysmal group, Type Ia endoleak by enhanced CT 7 days after TEVAR was detected in one patient in each group. Achievement of aortic remodeling was significantly better in narrow group. Aortic event occurred in only one patient in narrow group, in whom aortic expansion was observed. In aneurysmal group, aortic event occurred 12 patients (60%) and 2 RTAD, 5 SINE, and 8 aorta expansion were observed. Aortic event free rate was significantly better in narrow group.

Conclusion

TEVAR procedure for the TBAD patients with narrow true lumen seemed to be appropriate, however, different TEVAR procedure or additional procedures would be required for those with aneurysmal dilated false lumen to obtain favorable outcomes. (This is secondary publication from Jpn J Vasc Surg 2021; 30: 347-357.).

Для цитирования: Aoki Atsushi, Maruta Kazuto, Masuda Tomoaki, Omoto Tadashi. Procedure and Aortic Remodeling Effects of Entry Closure with Stentgraft for Type B Aortic Dissection: Comparison between the Patients with Narrow True Lumen and Those with Aneurysmal Dilated False Lumen.. Annals of vascular diseases. 2022. DOI: 10.3400/avd.oa.22-00089.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.