MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(98)80016-3

Медицинская библиотека · Journal of cataract and refractive surgery · 1998

Transscleral fixation of acrylic intraocular lenses in the absence of capsular support through 3.5 mm self-sealing incisions.

Oshima Y, Oida H, Emi K

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the safety and efficacy of transscleral ciliary sulcus fixation of acrylic intraocular lenses (IOLs) through small incisions in the management of secondary IOL implantation.

SETTING

Department of Ophthalmology, Osaka Rosai Hospital, Osaka, Japan.

METHODS

This retrospective study consisted of 28 patients (30 eyes) who had transscleral fixation of acrylic IOLs through 3.5 mm incisions. All patients were followed for a minimum of 6 months in several different clinical settings. Data on visual acuity, keratometry, and central corneal endothelial cell count were evaluated preoperatively and postoperatively. The refractive error achieved and incidence of postoperative complications were determined.

RESULTS

Uncorrected visual acuity (UCVA) improved in all eyes. Of the 18 eyes without pre-existing pathology, 11 (61.1%) had a UCVA of 20/40 or better from 1 week postoperatively. Best corrected visual acuity was unchanged in 24 eyes (80.0%) and improved by 2 Snellen lines or more in 5 eyes (16.7%) at the final examination. Self-sealing wound adaptation was achieved in 25 eyes (83.3%). The mean scalar shift in keratometric cylinder was 1.25 diopters (D) at 1 day postoperatively, 1.17 D at 1 week, and 1.06 D at 3 months. The rate of central corneal endothelial loss 6 months postoperatively averaged 7.84%. No intraoperative complications that were directly associated with acrylic IOL implantation occurred. Postoperative complications that included transient ocular hypertension, slight vitreous hemorrhage, and IOL malposition were found in a small population but resolved spontaneously without further surgical intervention.

CONCLUSIONS

The good visual outcomes and low incidence of complications achieved in the present study indicate that acrylic IOLs positioned through small incisions might be considered for ciliary sulcus fixation. However, evaluation of this technique in a large population over the long term is required.

Для цитирования: Oshima Y, Oida H, Emi K. Transscleral fixation of acrylic intraocular lenses in the absence of capsular support through 3.5 mm self-sealing incisions.. Journal of cataract and refractive surgery. 1998. DOI: 10.1016/s0886-3350(98)80016-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.