MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/ianc/9400881

Медицинская библиотека · International journal of analytical chemistry · 2026

Determination of Eight Benzene Homologs in Ambient Air and Indoor Air in Residential Areas by Secondary Thermal Desorption-Gas Chromatography.

Liu Tao, Yuan Xiaoxue, Yang Tiankuo, Yang Changxiao, Zhao Hui, Jiang Jiwen, Feng Jun

СтатьяПеревод в очереди

Аннотация

This study developed and comprehensively validated an optimized analytical method based on secondary thermal desorption-gas chromatography (STD-GC) for the simultaneous determination of eight key benzene homologs in ambient and indoor air of residential areas. Compared to solvent desorption and single-stage thermal desorption, STD demonstrates superior desorption efficiency, reduced matrix interference, fully automated rapid operation, complete analyte transfer, thereby eliminating analyte losses while enhancing analytical accuracy and sensitivity, and solvent-free ensuring friendly to human and the environment. Aiming at the characteristics of target compounds and complex environmental matrices (e.g., humidity, coexisting interferents), sampling parameters, thermal desorption conditions, and gas chromatographic separation conditions were systematically optimized, with particular emphasis on ensuring baseline separation of xylene isomers. The method demonstrated linearity over 10-1000 ng with correlation coefficients (R 2) > 0.992. The spiked recoveries of the method ranged between 90.5% and 117.3%, with relative standard deviations ranging between 0.8% and 9.2%, the detection limits ranged from 50 to 120 ng/m3, and the lower limits of quantitation ranged from 20 to 480 ng/m3. This study established a standardized and highly reliable analytical workflow, addressing the issues of parameter inconsistency and insufficient validation in existing methods when applied to paired residential-indoor air studies. Using this method, ambient and indoor air samples were synchronously collected and analyzed in residential areas. Results demonstrated significant correlations between indoor and outdoor concentrations of benzene homologs. This study also provides a methodological foundation and practical guidance for accurate assessment of residents' exposure to benzene homologs.

Для цитирования: Liu Tao, Yuan Xiaoxue, Yang Tiankuo, Yang Changxiao, Zhao Hui, Jiang Jiwen, Feng Jun. Determination of Eight Benzene Homologs in Ambient Air and Indoor Air in Residential Areas by Secondary Thermal Desorption-Gas Chromatography.. International journal of analytical chemistry. 2026. DOI: 10.1155/ianc/9400881.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.