Trimming a metallic biliary stent using an argon plasma coagulator.

Rerknimitr Rungsun, Naprasert Pisit, Kongkam Pradermchai, Kullavanijaya Pinit

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Distal migration is one of the common complications after insertion of a covered metallic stent. Stent repositioning or removal is not always possible in every patient. Therefore, trimming using an argon plasma coagulator (APC) may be a good alternative method to solve this problem.

METHODS

Metallic stent trimming by APC was performed in 2 patients with biliary Wallstent migration and in another patient with esophageal Ultraflex stent migration. The power setting was 60-100 watts with an argon flow of 0.8 l/min.

OBSERVATIONS: The procedure was successfully performed and all distal parts of the stents were removed. No significant collateral damage to the nearby mucosa was observed.

CONCLUSIONS

In a patient with a distally migrated metallic stent, trimming of the stent is possible by means of an APC. This new method may be applicable to other sites of metallic stent migration.

Для цитирования: Rerknimitr Rungsun, Naprasert Pisit, Kongkam Pradermchai, Kullavanijaya Pinit. Trimming a metallic biliary stent using an argon plasma coagulator.. Cardiovascular and interventional radiology. 2007. DOI: 10.1007/s00270-006-0013-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.