MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11325-023-02807-2

Медицинская библиотека · Sleep & breathing = Schlaf & Atmung · 2023

Adaptive servo-ventilation and mortality in patients with systolic heart failure and central sleep apnea: a single-center experience.

Sun Paulina, Porter Kyle, Randerath Winfried, Jarjoura David, Khayat Rami

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Central sleep apnea (CSA) is associated with increased mortality and morbidity in patients with heart failure with reduced ejection fraction (HFrEF). Treatment of CSA with a certain type of adaptive servo-ventilation (ASV) device that targets minute ventilation (ASVmv) was found to be harmful in these patients. A newer generation of ASV devices that target peak flow (ASVpf) is presumed to have different effects on ventilation and airway patency. We analyzed our registry of patients with HFrEF-CSA to examine the effect of exposure to ASV and role of each type of ASV device on mortality.

METHODS

This is a retrospective cohort study in patients with HFrEF and CSA who were treated with ASV devices between 2008 and 2015 at a single institution. Mortality data were collected through the institutional data honest broker. Usage data were obtained from vendors' and manufacturers' servers. Median follow-up was 64 months.

RESULTS

The registry included 90 patients with HFrEF-CSA who were prescribed ASV devices. Applying a 3-h-per-night usage cutoff, we found a survival advantage at 64 months for those who used the ASV device above the cutoff (n = 59; survival 76%) compared to those who did not (n = 31; survival 49%; hazard ratio 0.44; CI 95%, 0.20 to 0.97; P = 0.04). The majority (n = 77) of patients received ASVpf devices with automatically adjusting end-expiratory pressure (EPAP) and the remainder (n = 13) received ASVmv devices mostly with fixed EPAP (n = 12). There was a trend towards a negative correlation between ASVmv with fixed EPAP and survival.

CONCLUSION

In this population of patients with HFrEF and CSA, there was no evidence that usage of ASV devices was associated with increased mortality. However, there was evidence of differential effects of type of ASV technology on mortality.

Для цитирования: Sun Paulina, Porter Kyle, Randerath Winfried, Jarjoura David, Khayat Rami. Adaptive servo-ventilation and mortality in patients with systolic heart failure and central sleep apnea: a single-center experience.. Sleep & breathing = Schlaf & Atmung. 2023. DOI: 10.1007/s11325-023-02807-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.