MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.neuroimage.2017.04.068

Медицинская библиотека · NeuroImage · 2017

Combined PET and microdialysis for in vivo estimation of drug blood-brain barrier transport and brain unbound concentrations.

Gustafsson Sofia, Eriksson Jonas, Syvänen Stina, Eriksson Olof, Hammarlund-Udenaes Margareta, Antoni Gunnar

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Methods to investigate blood-brain barrier transport and pharmacologically active drug concentrations in the human brain are limited and data translation between species is challenging. Hence, there is a need to further develop the read-out of techniques like positron emission tomography (PET) for studying neuropharmacokinetics. PET has a high translational applicability from rodents to man and measures total drug concentrations in vivo. The aim of the present study was to investigate the possibility of translating total drug concentrations, acquired through PET, to unbound concentrations, resembling those measured in the interstitial fluid by microdialysis sampling. Simultaneous PET scanning and brain microdialysis sampling were performed in rats throughout a 60min infusion of [N-methyl-11C]oxycodone in combination with a therapeutic dose of oxycodone and during a 60min follow up period after the end of infusion. The oxycodone concentrations acquired with PET were converted into unbound concentrations by compensating for brain tissue binding and brain intracellular distribution, using the unbound volume of distribution in brain (Vu,brain), and were compared to microdialysis measurements of unbound concentrations. A good congruence between the methods was observed throughout the infusion. However, an accumulating divergence in the acquired PET and microdialysis data was apparent and became more pronounced during the elimination phase, most likely due to the passage of radioactive metabolites into the brain. In conclusion, the study showed that PET can be used to translate non-invasively measured total drug concentrations into unbound concentrations as long as the contribution of radiolabelled metabolites is minor or can be compensated for.

Для цитирования: Gustafsson Sofia, Eriksson Jonas, Syvänen Stina, Eriksson Olof, Hammarlund-Udenaes Margareta, Antoni Gunnar. Combined PET and microdialysis for in vivo estimation of drug blood-brain barrier transport and brain unbound concentrations.. NeuroImage. 2017. DOI: 10.1016/j.neuroimage.2017.04.068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.