MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s11671-026-04741-0

Медицинская библиотека · Discover nano · 2026

Detection of submicron titanium debris associated with peri-implantitis.

Kleinsorgen Françoise, Torres Orlanda, Ferreira Fernando, Henriques Bruno, Ramos António, Souza Júlio C M

СтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVE

The main aim of this study was to perform a systematic review on the detection of submicron-scale titanium debris at peri-implant tissues focusing on the analytical methods.

METHODS

A PRISMA-oriented systematic search was carried out on PubMed and Scopus using the following search items: titanium debris, submicron particles, peri-implantitis, analytical methods, inflammation, and implant failure. The inclusion criteria involved in vivo studies published in the English language, until November 26, 2025. Risk of bias was assessed using the ROBINS-I tool.

RESULTS

Previous studies reveal submicron-scale titanium debris at peri-implant tissues although the particles' detection depend on the microscopic method. High-resolution SEM and TEM images clearly showed titanium debris' dimensions below 1 µm although the heterogeneity of the studies revealed limitations on the particles' measurements. Some titanium particles were associated with oxidative stress and activation of pro-inflammatory cytokines to osteoclastogenesis (i.e., RANKL/RANK/OPG) and other inflammatory mediators such as IL-1β, IL-6, TNF-α, PGE2.

CONCLUSION

Thus, submicron titanium debris can be detected at peri-implant tissues that indicate the degradation of the materials and potential adverse biological effects in the human body. However, the analytical methods should involve high-resolution microscopy and a careful analysis of the images.

Для цитирования: Kleinsorgen Françoise, Torres Orlanda, Ferreira Fernando, Henriques Bruno, Ramos António, Souza Júlio C M. Detection of submicron titanium debris associated with peri-implantitis.. Discover nano. 2026. DOI: 10.1186/s11671-026-04741-0.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.