Combined Hybrid Procedure and VAD Insertion in 9 High-Risk Neonates and Infants With HLHS.

Bleiweis Mark S, Philip Joseph, Peek Giles J, Fudge James C, Sullivan Kevin J, Co-Vu Jennifer, Gupta Dipankar, Fricker Frederick Jay, Vyas Himesh V, Ebraheem Mohammed, Powers Emma R, Falasa Matheus, Jacobs Jeffrey P

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This report describes 9 high-risk neonates and infants with hypoplastic left heart syndrome (HLHS) who were stabilized with a combined hybrid approach and ventricular assist device (VAD) insertion (HYBRID+VAD) in preparation for heart transplantation.

METHODS

A total of 9 patients with HLHS (7 neonates, 2 infants) presented with anatomic or physiologic features associated with an increased risk for conventional univentricular palliation with the Norwood operation (large coronary sinusoids or fistulas, severe tricuspid regurgitation, cardiogenic shock, restrictive atrial septum). These patients underwent combined VAD insertion (Berlin EXCOR, Berlin Heart, Inc, Berlin, Germany) and Stage 1 hybrid palliation (application of bilateral pulmonary bands, stent placement in the patent arterial duct, and atrial septectomy if needed). During this same era, at the Congenital Heart Center, University of Florida, Gainesville, Florida, 46 neonates underwent a Norwood operation, 4 neonates underwent a hybrid approach "Stage 1" without VAD, and 3 patients with HLHS were supported with prostaglandin while awaiting heart transplantation.

RESULTS

At HYBRID+VAD insertion, the median age was 20 days (range, 13 to 143 days), and median weight was 3.25 kg (range, 2.43 to 4.2 kg). Six patients survive (67%), and 3 patients died (33%). Five survivors are at home doing well after successful heart transplantation, and 1 survivor is doing well in the intensive care unit on VAD support while awaiting transplantation. Only 1 of 6 survivors (16.7%) required intubation more than 10 days after HYBRID+VAD insertion. In 8 patients no longer undergoing VAD support, the median length of VAD support was 119.5 days (range, 56 to 196 days).

CONCLUSIONS

High-risk patients with HLHS who are suboptimal candidates for Norwood palliation can be successfully stabilized with pulsatile VAD insertion along with hybrid palliation while awaiting cardiac transplantation. These patients may be extubated and optimized for transplantation while undergoing VAD support.

Для цитирования: Bleiweis Mark S, Philip Joseph, Peek Giles J, Fudge James C, Sullivan Kevin J, Co-Vu Jennifer, Gupta Dipankar, Fricker Frederick Jay, Vyas Himesh V, Ebraheem Mohammed, Powers Emma R, Falasa Matheus, Jacobs Jeffrey P. Combined Hybrid Procedure and VAD Insertion in 9 High-Risk Neonates and Infants With HLHS.. The Annals of thoracic surgery. 2021. DOI: 10.1016/j.athoracsur.2021.05.073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.