MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(98)80049-7

Медицинская библиотека · Journal of cataract and refractive surgery · 1998

Endothelial damage with cataract surgery techniques.

Díaz-Valle D, Benítez del Castillo Sánchez J M, Castillo A, Sayagués O, Moriche M

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To evaluate intraoperative endothelial damage after planned extracapsular cataract extraction (ECCE) with difference capsulotomy techniques and phacoemulsification.

SETTING

San Carlos University Hospital, Castroviejo Institute, Madrid, Spain.

METHODS

In this prospective, randomized study, 60 patients with senile cataract scheduled for cataract surgery were divided into three groups of 20 each: Group 1 had phacoemulsification; Group 2, planned ECCE with continuous curvilinear capsulorhexis; and Group 3, ECCE with letter-box capsulotomy. Preoperatively and 3 months postoperatively, endothelial cell density, percentage of hexagonality, and the cell size variation coefficient were determined by contact specular microscopy; endothelial permeability was examined by anterior segment fluorophotometry and central corneal thickness, by ultrasonic pachymetry. Results were analyzed using the two-tailed Student's t-test and analysis of variance.

RESULTS

In all three groups, endothelial permeability and cell loss increased significantly from the preoperative values, but there were not significant differences among the postoperative values. Mean cell loss was 11.8% in Group 1, 12.8% in Group 2, and 10.1% in Group 3. There were no differences between the preoperative and postoperative morphometric indexes. Postoperative pachymetric measurements were not significant.

CONCLUSIONS

Endothelial response was not statistically significantly different among the surgical techniques, although endothelial damage was lower in Group 3, which could indicate a protective effect of the anterior capsule during cataract extraction. Endothelial barrier function remained disturbed despite the apparent morphological stabilization.

Для цитирования: Díaz-Valle D, Benítez del Castillo Sánchez J M, Castillo A, Sayagués O, Moriche M. Endothelial damage with cataract surgery techniques.. Journal of cataract and refractive surgery. 1998. DOI: 10.1016/s0886-3350(98)80049-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.