DOI 10.1016/j.clinph.2007.09.143

Медицинская библиотека · Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology · 2007

Electrodiagnostic criteria for diagnosis of ALS.

de Carvalho Mamede, Dengler Reinhard, Eisen Andrew, England John D, Kaji Ryuji, Kimura Jun, Mills Kerry, Mitsumoto Hiroshi, Nodera Hiroyuki, Shefner Jeremy, Swash Michael

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

A consensus meeting was held to determine the best use and interpretation of electrophysiological data in the diagnosis of ALS. The utility of needle EMG and nerve conduction studies was affirmed. It is recommended that electrophysiological evidence for chronic neurogenic change should be taken as equivalent to clinical information in the recognition of involvement of individual muscles in a limb. In addition, in the context of a suspected clinical diagnosis of ALS, fasciculation potentials should be taken as equivalent to fibrillation potentials and positive sharp waves in recognising denervation. The importance of searching for instability in fasciculation potentials and in motor unit potentials in ALS is stressed. These changes in the interpretation of electrophysiological data render obsolete the category Probable Laboratory-Supported ALS in the modified El Escorial diagnostic criteria for ALS. Methods for detection of upper motor neuron abnormality appear sensitive but require further study, particularly regarding their value when clinical signs of upper motor neuron lesion are uncertain.

Для цитирования: de Carvalho Mamede, Dengler Reinhard, Eisen Andrew, England John D, Kaji Ryuji, Kimura Jun, Mills Kerry, Mitsumoto Hiroshi, Nodera Hiroyuki, Shefner Jeremy, Swash Michael. Electrodiagnostic criteria for diagnosis of ALS.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2007. DOI: 10.1016/j.clinph.2007.09.143.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.