MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11255-007-9208-8

Медицинская библиотека · International urology and nephrology · 2007

Prostate biopsy in subjects with abnormal transrectal ultrasonography but normal digital examination findings and prostate-specific antigen levels.

Shim Hong Bang, Lee Sang Eun, Park Hyoung Keun, Ku Ja Hyeon

СтатьяПеревод в очереди

Аннотация

AIM: The aim of the present study was to evaluate the value of transrectal ultrasonography (TRUS) for prostate cancer diagnosis in men with no other indication for biopsy, such as an abnormal digital rectal examination or abnormally high prostate-specific antigen (PSA) levels.

MATERIALS AND

METHODS

The study cohort contained a total of 104 men aged 41-78 years (median 62.5 years) who had suspicious findings on TRUS. The median prostate volume of the patients was 33.0 ml (range 15.0-90.9) and the serum PSA ranged from 0.2 to 4.0 ng/ml (median 2.5 ng/ml).

RESULTS

Of 104 men, 12 (11.5%) were diagnosed with prostate cancer on initial biopsy. The positive predictive value (PPV) was 3.7% for PSA 0.1-1.0 ng/ml, 4.8% for PSA 1.1-2.0 ng/ml, 16.7% for PSA 2.1-3.0 ng/ml and 18.4% for PSA 3.1-4.0 ng/ml. The PPV for cancer with Gleason score 7 or higher was 0.0%, 0.0%, 16.7% and 7.9%, respectively. No statistically significant differences in patient characteristics and biopsy results were found between patients who received only systemic biopsy and those who received systemic plus lesion-directed biopsies.

CONCLUSION

The results of this study do not provide a rationale to recommend the additional use of lesion-directed biopsy in patients with suspicious lesions at TRUS but with no other indication for biopsy. Furthermore, our data raise the question of whether serum PSA levels lower than 4.0 ng/ml should be considered normal in Asian men.

Для цитирования: Shim Hong Bang, Lee Sang Eun, Park Hyoung Keun, Ku Ja Hyeon. Prostate biopsy in subjects with abnormal transrectal ultrasonography but normal digital examination findings and prostate-specific antigen levels.. International urology and nephrology. 2007. DOI: 10.1007/s11255-007-9208-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.