MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a8806

Медицинская библиотека · AJNR. American journal of neuroradiology · 2025

Simultaneous Multiparametric Estimation of AVM Hemodynamics Using MR Fingerprinting Arterial Spin-Labeling.

Hu Zhiyi, Jiang Dengrong, Shi Wen, Salim Hamza A, Lakhani Dhairya A, Xu Risheng, Huang Judy, Nael Kambiz, Lu Hanzhang, Yedavalli Vivek S

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Accurate hemodynamic characterization of cerebral AVMs is critical for treatment-planning, risk-stratification, and posttreatment monitoring but remains challenging due to their abnormal angioarchitecture. MR-fingerprinting (MRF) arterial spin-labeling (ASL) is a novel, noninvasive technique that enables simultaneous quantification of CBF, arterial CBV (aCBV), and bolus-arrival time (BAT) within a single 5-minute scan. This study evaluates the feasibility of MRF-ASL in assessing AVM hemodynamics and compares its sensitivity for AVM detection with CBF measurements obtained using single-delay pseudocontinuous ASL (pCASL).

MATERIALS AND

METHODS

Patients with DSA-confirmed AVMs were scanned on a 3T MRI system. Imaging protocols included MRF-ASL, standard single-delay pCASL, and T2-weighted MRI. MRF-ASL simultaneously-derived CBF, aCBV, and BAT, with CBF estimated using 2 kinetic models: a 1-compartment model, which reflects combined tissue and arterial contributions, and a 2-compartment model, which separates arterial signal from tissue perfusion. Regions of interest were manually drawn over the AVM nidus and contralateral nonaffected tissue. MRF-ASL parameters and pCASL-derived CBF were compared between the AVM nidus and nonaffected tissue. Additionally, linear regression analyses were conducted to examine the relationships among MRF-ASL parameters, single-delay pCASL CBF, and the Spetzler-Martin (SM) grade.

RESULTS

Six patients with AVMs with SM grades ranging from 1 to 5 were included in this study. MRF-ASL parameters revealed significantly elevated CBF1-compartment (AVM, 129.3 [SD, 21.5 mL/100 g/minute] versus nonaffected, 51.6 [SD, 23.9 mL/100 g/minute], P = .03), CBF2-compartment (AVM, 109.8 [SD, 24.4 mL/100 g/minute] versus nonaffected, 36.6 [SD, 18.6 mL/100 g/minute], P = .03), aCBV (AVM, 7.0 [SD, 4.5%] versus nonaffected, 0.6 [SD, 0.4%], P = .03), and shortened BAT (AVM, 784 [SD, 337 ms] versus nonaffected, 1099 [SD, 500 ms], P = .03) in the AVM nidus compared with contralateral nonaffected tissue in the same patient. In contrast, no significant difference was observed for pCASL CBF (AVM, 47.5 [SD, 49.2 mL/100 g/minute] versus nonaffected, 39.4 [SD, 14.0 mL/100 g/minute], P = .44). A significant positive correlation was identified between the SM grade and both CBF2-compartment (P = .006) and aCBV (P = .005). No association was found for CBF1-compartment (P = .12), BAT (P = .15), or pCASL CBF (P = .13).

CONCLUSIONS

In our preliminary study, MRF-ASL has the potential to provide comprehensive and multiparametric evaluation of AVM hemodynamics, demonstrating superior sensitivity for detecting AVM abnormalities compared with single-delay pCASL. These findings show the feasibility of MRF-ASL as a potentially useful tool for noninvasive characterization and monitoring of AVMs.

Для цитирования: Hu Zhiyi, Jiang Dengrong, Shi Wen, Salim Hamza A, Lakhani Dhairya A, Xu Risheng, Huang Judy, Nael Kambiz, Lu Hanzhang, Yedavalli Vivek S. Simultaneous Multiparametric Estimation of AVM Hemodynamics Using MR Fingerprinting Arterial Spin-Labeling.. AJNR. American journal of neuroradiology. 2025. DOI: 10.3174/ajnr.a8806.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.