MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bja.2026.02.001

Медицинская библиотека · British journal of anaesthesia · 2026

Improving interpretation of metabolic acid-base disorders by correcting pH-dependent bias in base excess partitioning.

Krbec Martin, Vančura Martin, Waldauf Petr, Heldeweg Micah L A, Giosa Lorenzo, Elbers Paul W G, Langer Thomas, Zadek Francesco, van Regenmortel Niels, Duška František

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Base excess (BE) partitioning is an established tool for bedside interpretation of metabolic acid-base disorders. However, this method assumes that changes in plasma strong ion difference, estimated as [Na+]-[Cl-], directly relate to changes in standard BE. This assumption holds in isolated plasma but fails in vivo, where pH-dependent redistribution between body compartments alters plasma strong ion difference without producing an equivalent change in standard BE. We hypothesised that this introduces a clinically relevant pH-dependent bias into BE partitioning and that adjusting the [Na+]-[Cl-] reference value for pH would correct it.

METHODS

Unmeasured ions were quantified using conventional BE partitioning and a novel pH-corrected version, in which the [Na+]-[Cl-] reference was adjusted by +1.5 mEq L-1 for every -0.1 change in pH. Agreement with strong ion gap was assessed in 5976 ICU patients from AmsterdamUMCdb using Bland-Altman analyses (including pH-stratified subgroups) and linear regression to quantify the independent effect of pH.

RESULTS

The conventional method demonstrated wide limits of agreement (-5.6 to 2.9 mEq L-1) and a strong confounding effect of pH (1.45 mEq L-1 per 0.1 pH unit). The pH-corrected algorithm markedly improved agreement with the strong ion gap (limits of agreement -4.4 to 0.4 mEq L-1) and substantially reduced the confounding effect of pH (0.15 mEq L-1 per 0.1 pH unit).

CONCLUSIONS

Conventional base excess partitioning is subject to a clinically relevant pH-dependent error. A variable, pH-adjusted [Na+]-[Cl-] reference value eliminates this error and provides a more reliable assessment of metabolic acid-base disturbances, especially in patients with severe acidaemia or alkalaemia.

Для цитирования: Krbec Martin, Vančura Martin, Waldauf Petr, Heldeweg Micah L A, Giosa Lorenzo, Elbers Paul W G, Langer Thomas, Zadek Francesco, van Regenmortel Niels, Duška František. Improving interpretation of metabolic acid-base disorders by correcting pH-dependent bias in base excess partitioning.. British journal of anaesthesia. 2026. DOI: 10.1016/j.bja.2026.02.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.