MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2009.11.023

Медицинская библиотека · The Journal of hand surgery · 2010

Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius.

Souer J Sebastiaan, Ring David, Matschke Stefan, Audige Laurent, Maren-Hubert Marta, Jupiter Jesse

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Open reduction and locked volar plate and screw fixation is a popular treatment method for extra-articular distal radius fractures with dorsal metaphyseal comminution. In this study, we compared the use of a titanium 2.4-mm precontoured plate with that of a stainless-steel oblique 3.5-mm T-shaped plate to test the null hypothesis that there would be no difference in wrist function or upper extremity-specific health status in the internal fixation of AO-type A3.2 distal radius fractures.

METHODS

We retrospectively analyzed 24 patients treated with a 2.4-mm titanium plate and 38 patients treated with a 3.5-mm stainless-steel plate for an extra-articular and dorsally angulated distal radius fracture, from data gathered in a prospective cohort study of plate and screw fixation of distal radius fractures. The 2 cohorts were analyzed for differences in motion, grip strength, pain, Gartland and Werley score, Disabilities of the Arm, Shoulder, and Hand score, and Short Form-36 score at 6, 12, and 24 months of follow-up. Group differences and their change over time were determined using regression analysis and the likelihood ratio test.

RESULTS

There were no significant differences in wrist function and arm-specific health status between patients treated with a 2.4-mm plate and those treated with a 3.5-mm plate at 6, 12, or 24 months of follow-up. However, we observed a trend toward greater wrist flexion at 1 year (66 degrees vs 55 degrees ; p=.07) and greater flexion-extension arc (137 degrees vs 123 degrees ; p=.08) and pronation-supination arc (172 degrees vs 160 degrees ; p=.07) at 24 months after surgery in patients treated with a 2.4-mm plate.

CONCLUSIONS

Patients with a dorsally angulated extra-articular distal radius facture can expect similar results when treated with either a precontoured 2.4-mm titanium plate or a 3.5-mm stainless-steel T-shaped plate.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic III.

Для цитирования: Souer J Sebastiaan, Ring David, Matschke Stefan, Audige Laurent, Maren-Hubert Marta, Jupiter Jesse. Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius.. The Journal of hand surgery. 2010. DOI: 10.1016/j.jhsa.2009.11.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.