m+Medelevator.RU
← Поиск публикаций
International orthopaedics · 2011

Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures--results of an international multicentre study.

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Konrad Gerhard, Hirschmüller Anja, Audige Laurent, Lambert Simon, Hertel Ralf, Südkamp Norbert P

Аннотация

PURPOSE: The aim of this study was to compare the functional outcome, quality of restoration, and complication rate after open reduction and internal fixation (ORIF) of displaced or unstable 2-, 3- and 4-part humeral fractures using two different locking plates.

METHODS: The data used in this analysis was prospectively collected in two large multicentre studies in 15 European Level 1 trauma centres. A total of 318 patients with proximal humeral fractures were treated with ORIF using either the locking proximal humerus plate (LPHP) or proximal humeral internal locking system (PHILOS). Outcome measurements included Constant and Neer scores, evaluation of local pain at the fracture site and complications, and radiographic assessment at one year.

RESULTS: At one year, the mean Constant scores (relative to the contralateral shoulder) improved significantly for both groups and were above 80% for 2-, 3-, and 4-part fractures. A significantly shorter surgical time, less pain at the fracture site, and better functional outcome was achieved by PHILOS-treated patients with 2-part fractures throughout the one-year follow-up month and with 3-part fractures at three months (p < 0.05). There was no difference between the treatment outcomes for 4-part fractures, and no difference in the complication rates (p > 0.05).

CONCLUSIONS: PHILOS and LPHP can be considered as useful implants for ORIF of displaced and unstable proximal humeral fractures. There was a slight advantage of the PHILOS system with regard to operative time and functional outcome, especially for the treatment of 2- and 3-part fractures.