MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/medsci14010115

Медицинская библиотека · Medical sciences (Basel, Switzerland) · 2026

Quantifying the Learning Curve in Ultrasound-Guided Vascular Access: Proficiency Metrics of Self-Taught Axillary Vein Puncture for CIED Implantation.

Vrachatis Dimitrios A, Papathanasiou Konstantinos A, Anagnostopoulos Ioannis, Giotaki Sotiria G, Kousta Maria, Karavasilis Christos, Piperis Christos, Tolios Panagiotis, Kaoukis Andreas, Raisakis Konstantinos, Giannopoulos Georgios, Papaioannou Theodore G, Siasos Gerasimos, Deftereos Spyridon

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ultrasound (US)-guided axillary vein puncture (AVP) is an established technique for cardiac implantable electronic device (CIED) implantation. Yet real-world data concerning shifting from conventional venous access into US-guided AVP are not widely available.

METHODS

This is a single-center prospective registry reporting safety (complications) and efficacy (success rate: i.e., accomplishment of the vein access utilizing only the initially employed approach) of self-taught US-guided AVP integration into the standard workflow of CIED procedures.

RESULTS

A total of 539 patients (mean age 71.5 ± 12.4 years old, 78.7% males) were treated in our institution over a three-year period. Regarding CIED type and lead number, 58.3% used an implantable cardioverter defibrillator, 32% used permanent pacemakers, and two leads were involved in 65.8% of the cases and three leads in 8.9%. Before integration of US-guided AVP, the venous access success rate was 93.5%. The US-guided AVP success rate was 377/400 procedures (94.2%). After the first semester of US-guided AVP utilization, a pattern of increased success rate was observed (p = 0.002) and remained stable over the following semesters. No major complication (periprocedural or 30-day mortality, hemothorax, pneumothorax and tamponade) occurred after US AVP integration in our workflow.

CONCLUSIONS

The integration of US-guided AVP in a self-taught manner is feasible among electrophysiologists with experience in US-guided vascular access. A high success rate can be reached quickly and safely.

Для цитирования: Vrachatis Dimitrios A, Papathanasiou Konstantinos A, Anagnostopoulos Ioannis, Giotaki Sotiria G, Kousta Maria, Karavasilis Christos, Piperis Christos, Tolios Panagiotis, Kaoukis Andreas, Raisakis Konstantinos, Giannopoulos Georgios, Papaioannou Theodore G, Siasos Gerasimos, Deftereos Spyridon. Quantifying the Learning Curve in Ultrasound-Guided Vascular Access: Proficiency Metrics of Self-Taught Axillary Vein Puncture for CIED Implantation.. Medical sciences (Basel, Switzerland). 2026. DOI: 10.3390/medsci14010115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.