MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1129729817752606

Медицинская библиотека · The journal of vascular access · 2018

Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?

Yıldırım İlknur, Tütüncü Ayşe Çiğdem, Bademler Süleyman, Özgür İlker, Demiray Mukaddes, Karanlık Hasan

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: To examine whether the real-time ultrasound-guided venipuncture for implantable venous port placement is safer than the traditional venipuncture.

METHODS

The study analyzed the results of 2153 venous ports placed consecutively from January 2009 to January 2016. A total of 922 patients in group 1 and 1231 patients in group 2 were admitted with venous port placed using the traditional landmark subclavian approach and real-time ultrasound-guided axillary approach, respectively. Sociodemographic characteristics of patients, early (pneumothorax, pinch-off syndrome, arterial puncture, hematoma, and malposition arrhythmia) and late (deep vein thrombosis, obstruction, infection, erosion-dehiscence, and rotation of the port chamber) complications and the association of these complications with the implantation method were evaluated.

RESULTS

There were no significant differences in the sociodemographic characteristics of the patients between the two groups. The overall and early complications in group 2 were significantly lower than those in group 1. Pinch-off syndrome only developed in group 1. Seven patients and two patients had pneumothorax in groups 1 and 2, respectively. Puncture number was significantly associated with the development of the overall complications.

CONCLUSION

The ultrasound-guided axillary approach may be preferred as a method to reduce the risk of both early and late complications. Large, randomized, controlled prospective trials will be helpful in determining a safer implantable venous port implantation technique.

Для цитирования: Yıldırım İlknur, Tütüncü Ayşe Çiğdem, Bademler Süleyman, Özgür İlker, Demiray Mukaddes, Karanlık Hasan. Does the real-time ultrasound guidance provide safer venipuncture in implantable venous port implantation?. The journal of vascular access. 2018. DOI: 10.1177/1129729817752606.