MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00268-022-06573-2

Медицинская библиотека · World journal of surgery · 2022

Severe Dysphagia is Rare After Magnetic Sphincter Augmentation.

Bologheanu Milena, Matic Aleksa, Feka Joy, Asari Reza, Bologheanu Razvan, Riegler Franz M, Gensthaler Lisa, Osmokrovic Bogdan, Schoppmann Sebastian F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Dysphagia remains the most significant concern after anti-reflux surgery, including magnetic sphincter augmentation (MSA). The aim of this study was to evaluate postoperative dysphagia rates, its risk factors, and management after MSA.

METHODS

From a prospectively collected database of all 357 patients that underwent MSA at our institution, a total of 268 patients were included in our retrospective study. Postoperative dysphagia score, gastrointestinal symptoms, proton pump inhibitor intake, GERD-HRQL, Alimentary Satisfaction, and serial contrast swallow imaging were evaluated within standardized follow-up appointments. To determine patients' characteristics and surgical factors associated with postoperative dysphagia, a multivariable logistic regression analysis was performed.

RESULTS

At a median follow-up of 23 months, none of the patients presented with severe dysphagia, defined as the inability to swallow solids or/and liquids. 1% of the patients underwent endoscopic dilatation, and 1% had been treated conservatively for dysphagia. 2% of the patients needed re-operation, most commonly due to recurrent hiatal hernia. Two patients underwent device removal due to unspecific discomfort and pain. No migration of the device or erosion by the device was seen. The LINX® device size ≤ 13 was found to be the only factor associated with postoperative dysphagia (OR 5.90 (95% CI 1.4-24.8)). The postoperative total GERD-HRQL score was significantly lower than preoperative total score (2 vs. 19; p = 0.001), and daily heartburn, regurgitations, and respiratory complains improved in 228/241 (95%), 131/138 (95%) and 92/97 (95%) of patients, respectively.

CONCLUSIONS

Dysphagia requiring endoscopic or surgical intervention was rare after MSA in a large case series. LINX® devices with a size < 13 were shown to be an independent risk factor for developing postoperative dysphagia.

Для цитирования: Bologheanu Milena, Matic Aleksa, Feka Joy, Asari Reza, Bologheanu Razvan, Riegler Franz M, Gensthaler Lisa, Osmokrovic Bogdan, Schoppmann Sebastian F. Severe Dysphagia is Rare After Magnetic Sphincter Augmentation.. World journal of surgery. 2022. DOI: 10.1007/s00268-022-06573-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.