MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/cce.0000000000000779

Медицинская библиотека · Critical care explorations · 2022

Ventilation Strategies During Extracorporeal Membrane Oxygenation for Neonatal Respiratory Failure: Current Approaches Among Level IV Neonatal ICUs.

Ibrahim John, Mahmood Burhan, DiGeronimo Robert, Rintoul Natalie E, Hamrick Shannon E, Chapman Rachel, Keene Sarah, Seabrook Ruth B, Billimoria Zeenia, Rao Rakesh, Daniel John, Cleary John, Sullivan Kevin, Gray Brian, Weems Mark, Dirnberger Daniel R

СтатьяПеревод в очереди

Аннотация

UNLABELLED: To describe ventilation strategies used during extracorporeal membrane oxygenation (ECMO) for neonatal respiratory failure among level IV neonatal ICUs (NICUs).

DESIGN

Cross-sectional electronic survey.

SETTING

Email-based Research Electronic Data Capture survey.

PATIENTS: Neonates undergoing ECMO for respiratory failure at level IV NICUs.

INTERVENTIONS: A 40-question survey was sent to site sponsors of regional referral neonatal ECMO centers participating in the Children's Hospitals Neonatal Consortium. Reminder emails were sent at 2- and 4-week intervals.

MEASUREMENTS AND MAIN

RESULTS

Twenty ECMO centers responded to the survey. Most primarily use venoarterial ECMO (65%); this percentage is higher (90%) for congenital diaphragmatic hernia. Sixty-five percent reported following protocol-based guidelines, with neonatologists primarily responsible for ventilator management (80%). The primary mode of ventilation was pressure control (90%), with synchronized intermittent mechanical ventilation (SIMV) comprising 80%. Common settings included peak inspiratory pressure (PIP) of 16-20 cm H2O (55%), positive end-expiratory pressure (PEEP) of 9-10 cm H2O (40%), I-time 0.5 seconds (55%), rate of 10-15 (60%), and Fio2 22-30% (65%). A minority of sites use high-frequency ventilation (HFV) as the primary mode (5%). During ECMO, 55% of sites target some degree of lung aeration to avoid complete atelectasis. Fifty-five percent discontinue inhaled nitric oxide (iNO) during ECMO, while 60% use iNO when trialing off ECMO. Nonventilator practices to facilitate decannulation include bronchoscopy (50%), exogenous surfactant (25%), and noninhaled pulmonary vasodilators (50%). Common ventilator thresholds for decannulation include PEEP of 6-7 (45%), PIP of 21-25 (55%), and tidal volume 5-5.9 mL/kg (50%).

CONCLUSIONS

The majority of level IV NICUs follow internal protocols for ventilator management during neonatal respiratory ECMO, and neonatologists primarily direct management in the NICU. While most centers use pressure-controlled SIMV, there is considerable variability in the range of settings used, with few centers using HFV primarily. Future studies should focus on identifying respiratory management practices that improve outcomes for neonatal ECMO patients.

Для цитирования: Ibrahim John, Mahmood Burhan, DiGeronimo Robert, Rintoul Natalie E, Hamrick Shannon E, Chapman Rachel, Keene Sarah, Seabrook Ruth B, Billimoria Zeenia, Rao Rakesh, Daniel John, Cleary John, Sullivan Kevin, Gray Brian, Weems Mark, Dirnberger Daniel R. Ventilation Strategies During Extracorporeal Membrane Oxygenation for Neonatal Respiratory Failure: Current Approaches Among Level IV Neonatal ICUs.. Critical care explorations. 2022. DOI: 10.1097/cce.0000000000000779.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.