MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2011.05.012

Медицинская библиотека · Journal of shoulder and elbow surgery · 2011

Radial head replacement with a bipolar system: a minimum 2-year follow-up.

Zunkiewicz Mark R, Clemente Jill S, Miller Mark C, Baratz Mark E, Wysocki Robert W, Cohen Mark S

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

We report the short-term results of a cohort of patients undergoing radial head replacement using a novel radial head prosthesis with a smooth, unfixed, telescoping stem and a bipolar design after a mean follow-up of 34 months (range, 24-48 months).

MATERIALS AND

METHODS

Patients were assessed using clinical and radiographic examination as well as with standardized outcome measures. Thirty implants (29 patients) were available for review.

RESULTS

At final follow-up, the average Mayo Elbow Performance Index Score was 92.1 and the Disabilities of the Arm, Shoulder, and Hand Score was 13.8. Clinical examination revealed significant differences between operative and nonoperative sides for flexion/extension and pronation/supination. Radiographic measurement of medial and lateral ulnohumeral spaces revealed re-establishment of a congruent elbow joint. No significant arthritic changes were identified at the radiocapitellar joint. Minimal angular migration of the implant in the proximal radial shaft was observed over time. Complications included 1 patient requiring temporary placement of a hinged external fixator for instability and 1 patient requiring revision surgery at 4 weeks.

CONCLUSION

This review demonstrates that a bipolar radial head prosthesis with a smooth stem and telescoping neck effectively restores stability to elbows with a comminuted radial head fracture and valgus instability. To date, this is the largest reported outcome analysis of bipolar radial head replacement in the literature.

Для цитирования: Zunkiewicz Mark R, Clemente Jill S, Miller Mark C, Baratz Mark E, Wysocki Robert W, Cohen Mark S. Radial head replacement with a bipolar system: a minimum 2-year follow-up.. Journal of shoulder and elbow surgery. 2011. DOI: 10.1016/j.jse.2011.05.012.

Предметные рубрики MeSH

Подготовка и перевод публикации