DOI 10.1186/s40001-025-03733-7
Effects of pelvic floor electrical stimulation with an implantable device at different frequencies on stress urinary incontinence in rats.
Аннотация
BACKGROUND
Most pelvic floor electrical stimulation (PFES) is intravaginal, with little research on how stimulation frequencies affect stress urinary incontinence (SUI) treatment. This study aimed to investigate the effects of different stimulation frequencies on improving SUI through PFES using an implantable PFES device in rats.
METHODS
A miniature, implantable, wireless PFES device (NuStim) was used to stimulate the pelvic floor muscles of 24 female Sprague-Dawley rats. All animals underwent vaginal distension (VD) to mimic postpartum SUI. PFES was applied at four frequencies (6 Hz, 15 Hz, 30 Hz and 50 Hz) to four experimental groups for 2 consecutive weeks. Multiple cystometrograms (CMGs) were performed to measure leak point pressure (LPP) and maximal bladder capacity (MBC).
RESULTS
VD-induced SUI significantly reduced the LPP to 21.1 ± 2.5 cmH2O, 24.1 ± 4.6 cmH2O, 24.0 ± 5.3 cmH2O and 25.7 ± 3.5 cmH2O compared to the control levels (46.5 ± 3.7 cmH2O, 50.1 ± 9.2 cmH2O, 49.3 ± 10.3 cmH2O and 53.3 ± 8.6 cmH2O, P < 0.01) across the four groups. PFES at 6 Hz, 15 Hz, 30 Hz and 50 Hz significantly increased the LPP to 50.9 ± 8.0 cmH2O, 53.3 ± 13.5 cmH2O, 49.6 ± 9.9 cmH2O and 54.0 ± 5.2 cmH2O compared to the respective VD levels (P < 0.001). No frequency-dependent differences were detected (P > 0.05). MBC did not show significant differences at any of the tested frequencies.
CONCLUSIONS
This study demonstrated that different PFES frequencies could all promote the recovery of urinary control function, with no significant differences in therapeutic effects. However, further randomized controlled studies were needed to assess additional frequencies and the long-term efficacy of PFES.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.