DOI 10.1177/1129729818758998

Медицинская библиотека · The journal of vascular access · 2018

Central venous catheterization for acute trauma resuscitation: Tip position analysis using routine emergency computed tomography.

Struck Manuel F, Ewens Sebastian, Schummer Wolfram, Busch Thilo, Bernhard Michael, Fakler Johannes K M, Stumpp Patrick, Stehr Sebastian N, Josten Christoph, Wrigge Hermann

СтатьяПеревод в очереди

Аннотация

PURPOSE: Central venous catheter insertion for acute trauma resuscitation may be associated with mechanical complications, but studies on the exact central venous catheter tip positions are not available. The goal of the study was to analyze central venous catheter tip positions using routine emergency computed tomography.

METHODS

Consecutive acute multiple trauma patients requiring large-bore thoracocervical central venous catheters in the resuscitation room of a university hospital were enrolled retrospectively from 2010 to 2015. Patients who received a routine emergency chest computed tomography were analyzed regarding central venous catheter tip position. The central venous catheter tip position was defined as correct if the catheter tip was placed less than 1 cm inside the right atrium relative to the cavoatrial junction, and the simultaneous angle of the central venous catheter tip compared with the lateral border of the superior vena cava was below 40°.

RESULTS

During the 6-year study period, 97 patients were analyzed for the central venous catheter tip position in computed tomography. Malpositions were observed in 29 patients (29.9%). Patients with malpositioned central venous catheters presented with a higher rate of shock (systolic blood pressure <90 mmHg) at admission (58.6% vs 33.8%, p = 0.023) and a higher mean injury severity score (38.5 ± 15.7 vs 31.6 ± 11.8, p = 0.041) compared with patients with correctly positioned central venous catheter tips. Logistic regression revealed injury severity score as a significant predictor for central venous catheter malposition (odds ratio = 1.039, 95% confidence interval = 1.005-1.074, p = 0.024).

CONCLUSION

Multiple trauma patients who underwent emergency central venous catheter placement by experienced anesthetists presented with considerable tip malposition in computed tomography, which was significantly associated with a higher injury severity.

Для цитирования: Struck Manuel F, Ewens Sebastian, Schummer Wolfram, Busch Thilo, Bernhard Michael, Fakler Johannes K M, Stumpp Patrick, Stehr Sebastian N, Josten Christoph, Wrigge Hermann. Central venous catheterization for acute trauma resuscitation: Tip position analysis using routine emergency computed tomography.. The journal of vascular access. 2018. DOI: 10.1177/1129729818758998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.