Jäckel Maria, Clivio Alessandro, Rey E Ambroa, Doolan Paul, Dumont Damien, Essers Marion, García Hernández Maria Trinitat, Gaudino Diego, Lizondo María, Lorenzen Ebbe Laugaard, Mankinen Mikko, Martin Albina Maria Luisa, Albaladejo M Martínez, Moreau-Noblet Caroline, Negri Anna, Novak Vaclav, Pellegri Luca, Poeta Sara, Prokofev Igor, Pytko Izabela, Sánchez-Artuñedo David, Sottiaux Alain, Uttman Karin, Walsh Keith, Koivumäki Tuomas

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Despite constant developments in radiotherapy, optimizing Volumetric Modulated Arc Therapy (VMAT) dose distributions for whole breast with extensive lymph node involvement remains a challenge. The aim of this study was to gain insights into clinical practices and to identify effective planning strategies.

METHODS

The participants of the European Federation of Organisations for Medical Physics VMAT Breast Working Group answered a survey regarding treatment planning routines for breast cancer irradiation and generated a treatment plan for a challenging patient case. The dose prescription was 50.4 Gy in 28 fractions for breast and lymph node volumes, and a simultaneous integrated boost (SIB) of 63 Gy.

RESULTS

The survey was completed by 25 participants and covered a wide spectrum of topics of VMAT treatment planning, including beam geometry and organs at risk (OAR) dose constraints. In addition, 22 plans were submitted for comparison. The mean doses ranged between: PTV breast 51.9---54.1 Gy, PTV lymph nodes 49.7---52.1 Gy, SIB 61.5---66.5 Gy, heart 1.5---9.5 Gy, ipsilateral lung 12.0---17.3 Gy, contralateral lung 1.2---6.5 Gy and contralateral breast 1.6---8.9 Gy. Five treatment planning strategies, with high target coverage and the lowest doses to organs at risk, are presented.

CONCLUSION

There is a wide variation in VMAT breast planning approaches, planning goals and prioritisation of PTVs and OARs across institutions. Descriptions of effective planning strategies for a challenging breast case are presented.

Для цитирования: Jäckel Maria, Clivio Alessandro, Rey E Ambroa, Doolan Paul, Dumont Damien, Essers Marion, García Hernández Maria Trinitat, Gaudino Diego, Lizondo María, Lorenzen Ebbe Laugaard, Mankinen Mikko, Martin Albina Maria Luisa, Albaladejo M Martínez, Moreau-Noblet Caroline, Negri Anna, Novak Vaclav, Pellegri Luca, Poeta Sara, Prokofev Igor, Pytko Izabela, Sánchez-Artuñedo David, Sottiaux Alain, Uttman Karin, Walsh Keith, Koivumäki Tuomas. Multi-institutional international investigation of VMAT treatment planning techniques for breast cancer with regional lymph nodes.. Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB). 2026. DOI: 10.1016/j.ejmp.2026.105844.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.