Talanta · 2024
A portable solid sampling visualization nano-sensor for soil Cd based on "three-phase transforming" technique.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Tengpeng, Huang Xudong, Wang Chunhui, Liu Jixin, Mao Xuefei
Аннотация
Direct analysis of solid samples is always challenging for ionic sensors due to solidified elemental presence and matrix interference. In this work, a "three-phase transforming" technique was first established to make solid sampling elemental sensors and visual detection possible in the future. For Cd transforming from soil samples, a metal ceramic heater (MCH) electrothermal vaporizer (ETV) coupled with a dielectric barrier discharge quartz trap (DBD-QT) was first utilized to fulfill the solid sampling and preconcentration of Cd in soil; for on-site analysis, a colorimetric sensor based on the trithiocyanuric acid (TMT) functionalized gold nanoparticles (AuNPs) was chosen as a chromogenic analysis model. The portable and miniature ETV-DBD apparatus directly introduced Cd from soil and then captured Cd, consuming only <130 W and 4.5 kg weight; finally, only 200 μL water was injected as eluent to dissolve Cd for the following colorimetric detection. Herein, the Cd analyte underwent a "three-phase transforming" from solid (Cd compounds in soil), to aerosol (vaporization and transportation), to solid (Cd oxides trapped on quartz surface) and to liquid (Cd2+ in eluate). Under optimized conditions, the method limit of detection (LOD) reached 0.04 mg/kg Cd (50 mg sample), fulfilling fast monitoring of Cd contamination in soil, with <20 % relative standard deviations (RSDs). The analysis time was <10 min excluding sample digestion and acid application, as well as the interference of Pb2+ on the AuNPs sensor can be eliminated via the "three-phase transforming" process, proving an excellent anti-interference for solid analysis. This "three-phase transforming" processing technique coupled with colorimetric sensor holds a great potential for direct and on-site analysis in solid samples without complicated handling, providing a fantastic methodology for the application of ionic sensors and making solid sampling elemental sensor and visual detection possible.