BACKGROUND

It is unclear whether fluid management goals are best achieved by bolus injection or continuous infusion of loop diuretics. In this study, we compared the effectiveness and safety of a continuous infusion with that of a bolus injection when an increased loop diuretic dosage is required in intensive care unit (ICU) patients.

METHODS

We obtained data from the MIMIC-III database for patients who were first-time ICU admissions and required an increased diuretic dosage. Patients were excluded if they had an estimated glomerular filtration rate <15 ml/min/1.73 m2, were receiving renal replacement therapy, had a baseline systolic blood pressure <80 mmHg, or required a furosemide dose <120 mg. The patients were divided into a continuous group and a bolus group. Propensity score matching was used to balance patients' background characteristics.

RESULTS

The final dataset included 807 patients (continuous group, n = 409; bolus group, n = 398). After propensity score matching, there were 253 patients in the bolus group and 231 in the continuous group. The 24 h urine output per 40 mg of furosemide was significantly greater in the continuous group than in the bolus group (234.66 ml [95% confidence interval (CI) 152.13-317.18, p < 0.01]). There was no significant between-group difference in the incidence of acute kidney injury (odds ratio 0.96, 95% CI 0.66-1.41, p = 0.85).

CONCLUSIONS

Our results indicate that a continuous infusion of loop diuretics may be more effective than a bolus injection and does not increase the risk of acute kidney injury in patients who need an increased diuretic dosage in the ICU.

Для цитирования: Weng Haoyu, Li Yuxi, Nie Xiaolu, He Chunhui, Feng Pengbin, Zhao Fengxin, Chen Qingjie, Sun Wen, Jiang Jie, Zhang Yan, Huo Yong, Li Jianping. Comparative effectiveness and safety of bolus vs. continuous infusion of loop diuretics: Results from the MIMIC-III Database.. The American journal of the medical sciences. 2022. DOI: 10.1016/j.amjms.2022.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.