MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2016.06.054

Медицинская библиотека · JACC. Cardiovascular interventions · 2016

Elimination of Transcoarctation Pressure Gradients Has No Impact on Left Ventricular Function or Aortic Shear Stress After Intervention in Patients With Mild Coarctation.

Keshavarz-Motamed Zahra, Rikhtegar Nezami Farhad, Partida Ramon A, Nakamura Kenta, Staziaki Pedro Vinícius, Ben-Assa Eyal, Ghoshhajra Brian, Bhatt Ami B, Edelman Elazer R

Клинический случайСтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This study sought to investigate the impact of transcatheter intervention on left ventricular function and aortic hemodynamics in patients with mild coarctation of the aorta (COA).

BACKGROUND

The optimal method and timing of transcatheter intervention for COA remains unclear, especially when the severity of COA is mild (peak-to-peak transcoarctation pressure gradient <20 mm Hg). Debate rages regarding the risk/benefit ratio of intervention versus long-term effects of persistent minimal gradient in this heterogeneous population with differing blood pressures, ventricular function, and peripheral perfusion.

METHODS

We developed a unique computational fluid dynamics and lumped parameter modeling framework based on patient-specific hemodynamic input parameters and validated it against patient-specific clinical outcomes (before and after intervention). We used clinically measured hemodynamic metrics and imaging of the aorta and the left ventricle in 34 patients with mild COA to make these correlations.

RESULTS

Despite dramatic reduction in the transcoarctation pressure gradient (catheter and Doppler echocardiography pressure gradients reduced by 75% and 47.3%, respectively), there was only modest effect on aortic flow and no significant impact on aortic shear stress (the maximum time-averaged wall shear stress in descending aorta was reduced 5.1%). In no patient did transcatheter intervention improve left ventricular function (e.g., stroke work and normalized stroke work were reduced by only 4.48% and 3.9%, respectively).

CONCLUSIONS

Transcatheter intervention that successfully relieves mild COA pressure gradients does not translate to decreased myocardial strain. The effects of the intervention were determined to the greatest degree by ventricular-vascular coupling hemodynamics and provide a novel valuable mechanism to evaluate patients with COA that may influence clinical practice.

Для цитирования: Keshavarz-Motamed Zahra, Rikhtegar Nezami Farhad, Partida Ramon A, Nakamura Kenta, Staziaki Pedro Vinícius, Ben-Assa Eyal, Ghoshhajra Brian, Bhatt Ami B, Edelman Elazer R. Elimination of Transcoarctation Pressure Gradients Has No Impact on Left Ventricular Function or Aortic Shear Stress After Intervention in Patients With Mild Coarctation.. JACC. Cardiovascular interventions. 2016. DOI: 10.1016/j.jcin.2016.06.054.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.