Медицинская библиотека · Emergency medicine journal : EMJ · 2013

Randomised trial comparing the recording ability of a novel, electronic emergency documentation system with the AHA paper cardiac arrest record.

Grigg Eliot, Palmer Andrew, Grigg Jeffrey, Oppenheimer Peter, Wu Tim, Roesler Axel, Nair Bala, Ross Brian

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the ability of an electronic system created at the University of Washington to accurately document prerecorded VF and pulseless electrical activity (PEA) cardiac arrest scenarios compared with the American Heart Association paper cardiac arrest record.

METHODS

16 anaesthesiology residents were randomly assigned to view one of two prerecorded, simulated VF and PEA scenarios and asked to document the event with either the paper or electronic system. Each subject then repeated the process with the other video and documentation method. Five types of documentation errors were defined: (1) omission, (2) specification, (3) timing, (4) commission and (5) noise. The mean difference in errors between the paper and electronic methods was analysed using a single factor repeated measures ANOVA model.

RESULTS

Compared with paper records, the electronic system omitted 6.3 fewer events (95% CI -10.1 to -2.5, p=0.003), which represents a 28% reduction in omission errors. Users recorded 2.9 fewer noise items (95% CI -5.3 to -0.6, p=0.003) when compared with paper, representing a 36% decrease in redundant or irrelevant information. The rate of timing (Δ=-3.2, 95% CI -9.3 to 3.0, p=0.286) and commission (Δ=-4.4, 95% CI -9.4 to 0.5, p=0.075) errors were similar between the electronic system and paper, while the rate of specification errors were about a third lower for the electronic system when compared with the paper record (Δ=-3.2, 95% CI -6.3 to -0.2, p=0.037).

CONCLUSIONS

Compared with paper documentation, documentation with the electronic system captured 24% more critical information during a simulated medical emergency without loss in data quality.

Для цитирования: Grigg Eliot, Palmer Andrew, Grigg Jeffrey, Oppenheimer Peter, Wu Tim, Roesler Axel, Nair Bala, Ross Brian. Randomised trial comparing the recording ability of a novel, electronic emergency documentation system with the AHA paper cardiac arrest record.. Emergency medicine journal : EMJ. 2013. DOI: 10.1136/emermed-2013-202512.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.