DOI 10.1007/s00595-022-02609-1
Tension-free thoracoscopic repair of congenital diaphragmatic hernia combined with a percutaneous extracorporeal closure technique: how to do it.
Аннотация
PURPOSE: Thoracoscopic repair (TR) of congenital diaphragmatic hernia (CDH) is associated with a higher recurrence rate than the conventional open method. We evaluated the effectiveness of our strategy for quality improvement, named "tension-free TR of CDH".
METHODS
The subjects of this retrospective analysis were 11 consecutive patients with CDH who underwent TR at our hospital between 2017 and 2021. Tension-free TR of CDH included the proactive use of an oversized patch for dome-shaped reconstruction and gapless suturing. We developed a percutaneous extracorporeal closure technique for secure suturing using a commercially available needle.
RESULTS
Patch repair was performed in 8 (73%) patients and none required conversion to open surgery because of technical difficulties. Recurrence developed in one patient (9%), who underwent successful reoperation via TR. All patients had an uneventful postoperative course.
CONCLUSION
Tension-free TR combined with extracorporeal closure could reduce the difficulty of suturing and the risk of recurrence of CDH.