OBJECTIVE

To investigate the outcomes of endoscopic optic nerve decompression (EOND) for bilateral traumatic optic neuropathy (TON).

METHODS

A retrospective analysis was conducted in 5 patients with bilateral TON, between January 2003 and December 2013. All the patients underwent preoperative ophthalmological evaluation, flash visual-evoked potentials, computed tomography scan, and systemic corticosteroid therapy. All the patients required an EOND surgery, due to poor response to medical therapy, and the remainder one was only treated with corticosteroid due to operative contraindication.

RESULTS

Of the 5 patients (10 eyes) undergoing EOND, visual acuity improved in 30% of eyes (n = 3) with a mean follow-up of 3 months. The remainder 7 eyes still had no light perception. All of the 5 patients undergoing EOND had no operative complications.

CONCLUSION

Treatment for bilateral TON should not be limited on the length of time to injury and visual-evoked potentials results. If surgical conditions permit and with no contraindications, patients should receive active surgical treatment as soon as possible.

Для цитирования: Xie Daoyu, Yu Hailing, Ju Jianbao, Zhang Li. The Outcome of Endoscopic Optic Nerve Decompression for Bilateral Traumatic Optic Neuropathy.. The Journal of craniofacial surgery. 2017. DOI: 10.1097/scs.0000000000003743.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.