DOI 10.1016/j.athoracsur.2016.06.002
Outcomes of Patients Receiving Temporary Circulatory Support Before Durable Ventricular Assist Device.
Аннотация
BACKGROUND
Temporary circulatory support (TCS) is used to stabilize patients in critical cardiogenic shock and bridge patients to a durable ventricular assist device (VAD). Whether TCS confers increased risk at the time of VAD implant is unknown.
METHODS
Prospectively collected data from five institutions was retrospectively reviewed. All profile 1 through profile 3 patients implanted with a continuous-flow VAD (n = 804) were categorized into three groups: TCS (n = 68); non-TCS profile 1 (n = 70); and non-TCS profile 2-3 (n = 666).
RESULTS
End-organ function and hemodynamics were worse before TCS than in non-TCS profile 1 patients: creatinine (1.7 ± 0.1 mg/dL versus 1.3 ± 0.06 mg/dL, p = 0.003); and right atrial pressure (16 ± 0.8 mm Hg versus 13 ± 1.1 mm Hg, p = 0.048). The TCS restored cardiac output before durable VAD (4.9 ± 0.2 L/min), and was comparable to profile 2-3 patients (4.3 ± 0.05 L/min) and better than profile 1 patients (4.0 ± 0.2 L/min, p = 0.002). Markers of hepatic function such as bilirubin were impaired before VAD in TCS and profile 1 patients (2.0 ± 0.2 mg/dL) compared with profile 2 and 3 patients (1.1 ± 0.03, p < 0.001). The incidence of postoperative right ventricular failure necessitating a right VAD was 21% for TCS patients and non-TCS profile 1 patients compared with 2% for profile 2-3 patients (p < 0.001). Profile 1 and TCS patients had similar 1-year survival (70% and 77%, p = 0.57), but inferior survival as compared with profile 2 and 3 patients (82%, p < 0.001). On multivariable analysis, TCS increased the hazard of death twofold.
CONCLUSIONS
Temporary circulatory support restores hemodynamics and reverses end-organ dysfunction. Nevertheless, these patients have high residual risk with postoperative morbidity and mortality that parallels profile 1 patients without TCS. Caution is suggested in downgrading risk for TCS patients with improved hemodynamic stability.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.