MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aju.2013.08.014

Медицинская библиотека · Arab journal of urology · 2013

The role of an abnormal prostate-specific antigen level and an abnormal digital rectal examination in the diagnosis of prostate cancer: A cross-sectional study in Qatar.

Al Rumaihi Khalid, Al Jalham Khalid, Younes Nagy, Majzoub Ahmad A, Shokeir Ahmed A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To investigate the role of an abnormal prostate-specific antigen (PSA) level and abnormal findings on a digital rectal examination (DRE) in the detection of prostate cancer in men in Qatar.

PATIENTS AND

METHODS

Between June 2008 and September 2012, 651 patients had a transrectal ultrasonography-guided biopsy of the prostate (TRUSBP) at our centre. The indications for a biopsy were a high PSA level (>4 ng/mL), or an abnormal DRE result. Patients were assessed by a thorough history, clinical examination and routine laboratory investigations. Data, including age, DRE findings, TRUS findings, total PSA level, prostate volume and the pathology results, were evaluated.

RESULTS

The mean (SD) age of the 651 patients was 64.1 (7.4) years. Prostate cancer was detected in 181 men (27.8%), benign prostatic hyperplasia in 275 (42.2%) and prostatitis in 236 (36.4%). The sensitivity and specificity for detecting prostate cancer were 93.9% and 8.5% for an abnormal PSA level (>4 ng/mL), 46.1% and 84.7% for abnormal DRE findings, and 95% and 30.2% for the two combined. Using a receiver operating characteristics curve, a PSA threshold of 7.9 ng/mL had a sensitivity of 56.6% and specificity of 52.8%. When a PSA threshold of 7.9 ng/mL was used in combination with abnormal DRE findings, the overall accuracy was 76.9%.

CONCLUSION

The PSA threshold level of 7.9 ng/mL, determined by this analysis, has a higher likelihood of detecting prostate cancer in men in Qatar. However, it failed to detect cancer in substantially many men with statistically significant disease.

Для цитирования: Al Rumaihi Khalid, Al Jalham Khalid, Younes Nagy, Majzoub Ahmad A, Shokeir Ahmed A. The role of an abnormal prostate-specific antigen level and an abnormal digital rectal examination in the diagnosis of prostate cancer: A cross-sectional study in Qatar.. Arab journal of urology. 2013. DOI: 10.1016/j.aju.2013.08.014.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.