m+Medelevator.RU
← Поиск публикаций
Magnetic resonance in medicine · 2026

1D Pre-Acquisition Navigator Correcting Respiratory-Induced Field Fluctuations in Multi-Echo Gradient-Echo Imaging of the Thoracic Spinal Cord.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cronin Alicia E, D'Astous Alexandre, Williams Nathan, Guénette Antoine, Salakhov Aimee, Stubblefield Seth, McKnight Colin D, Narisetti Lipika, Sriram Subramaniam, Smith Seth A, Robison Ryan K, Gilbert Guillaume, Cohen-Adad Julien, O'Grady Kristin P

Аннотация

PURPOSE: In the spinal cord (SC), multi-echo gradient echo (ME-GRE) increases gray (GM) and white matter (WM) contrast and improves sensitivity to lesions in people with multiple sclerosis (pwMS). However, SC ME-GRE is susceptible to breathing-induced field fluctuations, causing ghosting artifacts and signal loss. Recent work introduced a 1D phase navigator following the last echo to measure field variations; however, susceptibility to phase wrapping increases at longer echo times. We propose a 1D phase navigator preceding the first echo, reducing phase accumulation and eliminating the need for respiratory monitoring.

METHODS: ME-GRE data covering the lower (T9-T12 vertebrae) and upper (T4-T8 vertebrae) thoracic SC were acquired in 20 healthy volunteers and 3 pwMS at 3T. Standard and navigator-corrected images were acquired in the same acquisition. To evaluate image quality, WM and GM signal-to-noise ratio (SNR), WM/GM contrast-to-noise ratio (CNR), and background ghosting signals were measured and compared between the two reconstructions. Both were blindly assessed for artifacts, structural delineation, and diagnostic confidence in pwMS.

RESULTS: Navigator correction significantly increased GM and WM SNR and CNR, reduced posterior ghosting across both thoracic regions, and significantly reduced artifacts while increasing structural delineation. Preliminary evaluation in three pwMS showed consistent improvements in artifact mitigation, structural delineation, and lesion conspicuity with navigator correction, providing proof-of-concept for potential clinical application.

CONCLUSION: A 1D navigator prior to the first echo reduces ghosting and improves thoracic SC image quality without respiratory monitoring. This approach could improve the diagnostic value and enhance the reliability of thoracic SC ME-GRE.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты